科技报告详细信息
High Performance Window Retrofit
Shrestha, Som S1  Hun, Diana E1  Desjarlais, Andre Omer1 
[1] ORNL
关键词: Window;    EnergyPlus;    Flexible Research Platform;    high performance;   
DOI  :  10.2172/1122690
RP-ID  :  ORNL/TM-2013/560
PID  :  OSTI ID: 1122690
Others  :  Other: BT0304030
Others  :  CEBT314
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

The US Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) and Traco partnered to develop high-performance windows for commercial building that are cost-effective. The main performance requirement for these windows was that they needed to have an R-value of at least 5 ft2 F h/Btu. This project seeks to quantify the potential energy savings from installing these windows in commercial buildings that are at least 20 years old. To this end, we are conducting evaluations at a two-story test facility that is representative of a commercial building from the 1980s, and are gathering measurements on the performance of its windows before and after double-pane, clear-glazed units are upgraded with R5 windows. Additionally, we will use these data to calibrate EnergyPlus models that we will allow us to extrapolate results to other climates. Findings from this project will provide empirical data on the benefits from high-performance windows, which will help promote their adoption in new and existing commercial buildings. This report describes the experimental setup, and includes some of the field and simulation results.

【 预 览 】
附件列表
Files Size Format View
RO201704180000307LZ 733KB PDF download
  文献评价指标  
  下载次数:15次 浏览次数:44次