科技报告详细信息
RHIC 100 GeV Polarized Proton Luminosity
Zhang, S. Y.1 
[1]Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.
关键词: PROTON BEAMS;    BEAM LUMINOSITY;    GEV RANGE 10-100;    POLARIZED BEAMS;    BROOKHAVEN RHIC;    LIFETIME;    ELECTRIC POTENTIAL;    LOSSES;    BEAM EMITTANCE Relativistic Heavy Ion Collider;   
DOI  :  10.2172/1119568
RP-ID  :  BNL--103712-2014-IR
RP-ID  :  BNL--C-A/AP/500
PID  :  OSTI ID: 1119568
Others  :  R&D Project: KBCH139
Others  :  18031
Others  :  Other: KB0202011
Others  :  TRN: US1500093
学科分类:核物理和高能物理
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
A big problem in RHIC 100 GeV proton run 2009 was the significantly lower luminosity lifetime than all previous runs. It is shown in this note that the beam intensity decay in run 2009 is caused by the RF voltage ramping in store. It is also shown that the beam decay is not clearly related to the beam momentum spread, therefore, not directly due to the 0.7m. ??* Furthermore, the most important factor regarding the low luminosity lifetime is the faster transverse emittance growth in store, which is also much worse than the previous runs, and is also related to the RF ramping. In 100 GeV proton run 2012a, the RF ramping was abandoned, but the ??* was increased to 0.85m, with more than 20% loss of luminosity, which is not necessary. It is strongly suggested to use smaller ??* in 100 GeV polarized proton run 2015/2016
【 预 览 】
附件列表
Files Size Format View
949KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:19次