科技报告详细信息
Passive Room-to-Room Air Transfer, Fresno, California (Fact Sheet)
关键词: RESIDENTIAL;    RESIDENTIAL BUILDINGS;    IBACOS;    BUILDING AMERICA;    FIELD TEST RESULTS;    COMPUTATIONAL FLUID DYNAMICS;    CFD;    ROOM-TO-ROOM UNIFORMITY;    MINI-SPLIT;    SINGLE POINT;    HVAC;    FRESNO;    CALIFORNIA;    RETROFIT UNOCCUPIED TEST HOUSE;    MODEL VALIDATION;    ACCA MANUAL RS;    ASHRAE STANDARD 55;    OCCUPANT COMFORT;    SPACE CONDITIONING;    50% BA BENCHMARK;    HOT MIXED-DRY;    LOW AIRFLOW;    SIMPLIFIED SPACE CONDITIONING;   
DOI  :  10.2172/1122311
RP-ID  :  DOE/GO-102014-4300
PID  :  OSTI ID: 1122311
Others  :  Other: KNDJ-0-40341-00
学科分类:能源(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

Field testing was performed in a retrofit unoccupied test house in Fresno, California. Three air-based heating, ventilation, and air conditioning (HVAC) distribution systems - a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms - were evaluated during heating, cooling, and midseason conditions. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics (CFD) modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

【 预 览 】
附件列表
Files Size Format View
647KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:43次