科技报告详细信息
Final Assessment of Manual Ultrasonic Examinations Applied to Detect Flaws in Primary System Dissimilar Metal Welds at North Anna Power Station
Anderson, Michael T. ; Diaz, Aaron A. ; Cinson, Anthony D. ; Crawford, Susan L. ; Prowant, Matthew S. ; Doctor, Steven R.
关键词: dissimilar metal weld;    cracks;    ultrasonic testing;    site-specific mock-up;   
DOI  :  10.2172/1130661
RP-ID  :  PNNL-22553
PID  :  OSTI ID: 1130661
Others  :  Other: 401001060
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

PNNL conducted a technical assessment of the NDE issues and protocols that led to missed detections of several axially oriented flaws in a steam generator primary inlet dissimilar metal weld at North Anna Power Station, Unit 1 (NAPS-1). This particular component design exhibits a significant outside-diameter (OD) taper that is not included as a blind performance demonstration mock-up within the industry???s Performance Demonstration Initiative, administered by EPRI. For this reason, the licensee engaged EPRI to assist in the development of a technical justification to support the basis for a site-specific qualification. The service-induced flaws at NAPS-1 were eventually detected as a result of OD surface machining in preparation for a full structural weld overlay. The machining operation uncovered the existence of two through-wall flaws, based on the observance of primary water leaking from the dissimilar metal weld. A total of five axially oriented flaws were detected in varied locations around the weld circumference. The field volumetric examination that was conducted at NAPS-1 was a non-encoded, real-time manual ultrasonic examination. PNNL conducted both an initial assessment, and subsequently, a more rigorous technical evaluation (reported here), which has identified an array of NDE issues that may have led to the subject missed detections. These evaluations were performed through technical reviews and discussions with NRC staff, EPRI NDE Center personnel, industry and ISI vendor personnel, and ultrasonic transducer manufacturers, and laboratory tests, to better understand the underlying issues at North Anna.

【 预 览 】
附件列表
Files Size Format View
36074KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:22次