科技报告详细信息
Hanford Apatite Treatability Test Report Errata: Apatite Mass Loading Calculation
Szecsody, James E. ; Vermeul, Vincent R. ; Williams, Mark D. ; Truex, Michael J.
关键词: remediation;    apatite;    strontium;   
DOI  :  10.2172/1149238
RP-ID  :  PNNL-23367
PID  :  OSTI ID: 1149238
Others  :  Other: 830403000
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
The objective of this errata report is to document an error in the apatite loading (i.e., treatment capacity) estimate reported in previous apatite treatability test reports and provide additional calculation details for estimating apatite loading and barrier longevity. The apatite treatability test final report (PNNL-19572; Vermeul et al. 2010) documents the results of the first field-scale evaluation of the injectable apatite PRB technology. The apatite loading value in units of milligram-apatite per gram-sediment is incorrect in this and some other previous reports. The apatite loading in units of milligram phosphate per gram-sediment, however, is correct, and this is the unit used for comparison to field core sample measurements.
【 预 览 】
附件列表
Files Size Format View
497KB PDF download
  文献评价指标  
  下载次数:12次 浏览次数:37次