Characterization of basin concrete in support of structural integrity demonstration for extended storage
Duncan, A.1 
[1] Savannah River National Laboratory, Aiken, SC (United States)
关键词: Concrete;    Mechanical Properties;    Environmental Degradation;    Microstructure;   
DOI  :  10.2172/1159181
RP-ID  :  SRNL-STI--2014-00364
PID  :  OSTI ID: 1159181
Others  :  TRN: US1400452
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

Concrete core samples from C basin were characterized through material testing and analysis to verify the design inputs for structural analysis of the L Basin and to evaluate the type and extent of changes in the material condition of the concrete under extended service for fuel storage. To avoid the impact on operations, core samples were not collected from L area, but rather, several concrete core samples were taken from the C Basin prior to its closure. C basin was selected due to its similar environmental exposure and service history compared to L Basin. The microstructure and chemical composition of the concrete exposed to the water was profiled from the water surface into the wall to evaluate the impact and extent of exposure. No significant leaching of concrete components was observed. Ingress of carbonation or deleterious species was determined to be insignificant. No evidence of alkali-silica reactions (ASR) was observed. Ettringite was observed to form throughout the structure (in air voids or pores); however, the sulfur content was measured to be consistent with the initial concrete that was used to construct the facility. Similar ettringite trends were observed in the interior segments of the core samples. The compressive strength of the concrete at the mid-wall of the basin was measured, and similar microstructural analysis was conducted on these materials post compression testing. The microstructure was determined to be similar to near-surface segments of the core samples. The average strength was 4148 psi, which is well-above the design strength of 2500 psi. The analyses showed that phase alterations and minor cracking in a microstructure did not affect the design specification for the concrete.

【 预 览 】
附件列表
Files Size Format View
7471KB PDF download
  文献评价指标  
  下载次数:29次 浏览次数:49次