科技报告详细信息
The Development of an INL Capability for High Temperature Flow, Heat Transfer, and Thermal Energy Storage with Applications in Advanced Small Modular Reactors, High Temperature Heat Exchangers, Hybrid Energy Systems, and Dynamic Grid Energy Storage C
Sun, Xiaodong1  Zhang, Xiaoqin1  Kim, Inhun1  O'Brien, James2 
[1]The Ohio State Univ., Columbus, OH (United States)
[2]Idaho National Lab. (INL), Idaho Fall
关键词: NATURAL CONVECTION;    FORCED CONVECTION;    MOLTEN SALTS;    HEAT LOSSES;    COOLANT LOOPS;    HELIUM;    TEMPERATURE RANGE 0400-1000 K;    FLUORIDES;    HEAT EXCHANGERS;    HEAT STORAGE;    RECOMMENDATIONS;    MSRE REACTOR;    THERMAL HYDRAULICS;    CONNECTORS;    DESIGN;    FLOWMETERS;    PERFORMANCE;    PRINTED CIRCUITS;    CORROSION;    HYBRID SYSTEMS;    ENERGY STORAGE;    FLUID FLOW;    TEST FACILITIES;    CHEMICAL REACTIONS;    COMPATIBILITY;    CONTROL;    OPERATION;    SIZE;    MODULAR STRUCTURES;    PIPES;    CALCULATION METHODS;    MATHEMATICAL MODELS;    THERMAL INSULATION;    POWER SYSTEMS;    TEMPERATURE DEPENDENCE;    CHEMICAL PREPARATION;   
DOI  :  10.2172/1237324
RP-ID  :  INL/EXT--14-33562
PID  :  OSTI ID: 1237324
Others  :  TRN: US1600307
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
The overall goal of this project is to support Idaho National Laboratory in developing a new advanced high temperature multi fluid multi loop test facility that is aimed at investigating fluid flow and heat transfer, material corrosion, heat exchanger characteristics and instrumentation performance, among others, for nuclear applications. Specifically, preliminary research has been performed at The Ohio State University in the following areas: 1. A review of fluoride molten salts??? characteristics in thermal, corrosive, and compatibility performances. A recommendation for a salt selection is provided. Material candidates for both molten salt and helium flow loop have been identified. 2. A conceptual facility design that satisfies the multi loop (two coolant loops [i.e., fluoride molten salts and helium]) multi purpose (two operation modes [i.e., forced and natural circulation]) requirements. Schematic models are presented. The thermal hydraulic performances in a preliminary printed circuit heat exchanger (PCHE) design have been estimated. 3. An introduction of computational methods and models for pipe heat loss analysis and cases studies. Recommendations on insulation material selection have been provided. 4. An analysis of pipe pressure rating and sizing. Preliminary recommendations on pipe size selection have been provided. 5. A review of molten fluoride salt preparation and chemistry control. An introduction to the experience from the Molten Salt Reactor Experiment at Oak Ridge National Laboratory has been provided. 6. A review of some instruments and components to be used in the facility. Flowmeters and Grayloc connectors have been included. This report primarily presents the conclusions drawn from the extensive review of literatures in material selections and the facility design progress at the current stage. It provides some useful guidelines in insulation material and pipe size selection, as well as an introductory review of facility process and components.
【 预 览 】
附件列表
Files Size Format View
19878KB PDF download
  文献评价指标  
  下载次数:18次 浏览次数:83次