RHIC prefire protection masks | |
Drees, A. ; Biscardi, C. ; Curcio, T. ; Gassner, D. ; DeSanto, L. ; Fu, W. ; Liaw, C. J. ; Montag, C. ; Thieberger, P. ; Yip, K. | |
关键词: BROOKHAVEN RHIC; APERTURES; SAFETY; WALLS; ACCELERATOR FACILITIES; RADIATION DETECTORS; PHYSICAL RADIATION EFFECTS; IRRADIATION; KICKER MAGNETS; FAILURES Relativistic Heavy Ion Collider; | |
DOI : 10.2172/1172085 RP-ID : BNL--107380-2015-IR RP-ID : BNL--C-A/AP/533 PID : OSTI ID: 1172085 Others : R&D Project: 18031 Others : KBCH139 Others : Other: KB0202011 Others : TRN: US1500137 |
|
学科分类:核物理和高能物理 | |
美国|英语 | |
来源: SciTech Connect | |
【 摘 要 】
The protection of the RHIC experimental detectors from damage due to beam hitting close upstream elements in cases of abort kicker prefires requires some dedicated precautionary measures with two general options: to bring the beam close to a limiting aperture (i.e. the beam pipe wall), as far upstream of the detector components as possible or, alternatively, to bring a limiting aperture close to the circulating beam. Spontaneous and random prefires of abort kicker modules (Pulse Forming Network, PFN) have a history as long as RHIC is being operated. The abort system consist of 5 kickers in per ring, each of them equipped with its own dedicated PFN.