科技报告详细信息
Investigating Solutions to Wind Washing Issues in Two-Story Florida Homes, Phase 2
Withers, C.1  Kono, J.1 
[1] Building America Partnership for Improved Residential Construction, Cocoa, FL (United States)
关键词: residential;    Residential Buildings;    BA-PIRC;    Building America;    wind washing;    floor cavity;    attic space;    thermal barrier;    air barrier;    uncontrolled infiltration;    duct tightness;    pressure testing;    Retrofit;    existing homes;    cooling impacts;    heating impacts;    multi-story;   
DOI  :  10.2172/1220445
RP-ID  :  DOE/GO--102015-4595
PID  :  OSTI ID: 1220445
Others  :  Other: 7053
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

This report provides results from a second-phase research study of a phenomenon generally referred to as wind washing. Wind washing is the movement of unconditioned air around or through building thermal barriers in such a way as to diminish or nullify the intended thermal performance. In some cases, thermal and air barriers are installed very poorly or not at all, and air can readily move from unconditioned attic spaces into quasi-conditioned interstitial spaces. This study focused on the impact of poorly sealed and insulated floor cavities adjacent to attic spaces in Florida homes. In these cases, unconditioned attic air can be transferred into floor cavities through pathways driven by natural factors such as wind, or by thermal differences between the floor cavity and the attic. Air can also be driven into a floor cavity through mechanical forces imposed by return duct leakage in the floor cavity.

【 预 览 】
附件列表
Files Size Format View
4570KB PDF download
  文献评价指标  
  下载次数:34次 浏览次数:35次