科技报告详细信息
Multifamily Envelope Leakage Model | |
Faakye, O.1  Griffiths, D.1  | |
[1] Consortium for Advanced Residential Buildings, Norwalk, CT (United States) | |
关键词: residential; Residential Buildings; CARB; Building America; blower door testing; envelope leakage; single-family attached housing; multifamily apartments; guarded; unguarded; predicting fully guarded test results; Building America; CARB; empirical model; multi-linear regression model; | |
DOI : 10.2172/1220450 RP-ID : DOE/GO--102015-4499 PID : OSTI ID: 1220450 Others : Other: 7061 |
|
美国|英语 | |
来源: SciTech Connect | |
【 摘 要 】
The objective of the 2013 research project was to develop the model for predicting fully guarded test results (FGT), using unguarded test data and specific building features of apartment units. The model developed has a coefficient of determination R2 value of 0.53 with a root mean square error (RMSE) of 0.13. Both statistical metrics indicate that the model is relatively strong. When tested against data that was not included in the development of the model, prediction accuracy was within 19%, which is reasonable given that seasonal differences in blower door measurements can vary by as much as 25%.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
1033KB | download |