科技报告详细信息
Innovative Retrofit Insulation Strategies for Concrete Masonry Foundations
Huelman, P.1  Goldberg, L.1  Jacobson, R.1 
[1] NorthernSTAR, St. Paul, MN (United States)
关键词: residential;    Residential Buildings;    NorthernSTAR;    Building America;    CMU's;    concrete block foundations;    core fill;    moisture in concrete blocks;    foundation heat loss;    wet basements;    cold basements;    foundation experimental research;    number of basements in cold climates;   
DOI  :  10.2172/1220448
RP-ID  :  DOE/GO--102015-4538
PID  :  OSTI ID: 1220448
Others  :  Other: 7058
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

Basements in climates 6 and 7 can account for a fraction of a home's total heat loss when fully conditioned. Such foundations are a source of moisture, with convection in open block cavities redistributing water from the wall base, usually when heating. Even when block cavities are capped, the cold foundation concrete can act as a moisture source for wood rim joist components that are in contact with it. Because below-grade basements are increasingly used for habitable space, cold foundation walls pose challenges for moisture contribution, energy use, and occupant comfort.

【 预 览 】
附件列表
Files Size Format View
9926KB PDF download
  文献评价指标  
  下载次数:71次 浏览次数:47次