【 摘 要 】

This report presents an evaluation of a hypothetical INL Site monitoring network and the existing INL air monitoring network using frequency of detection methods. The hypothetical network was designed to address the requirement in 40 CFR Part 61, Subpart H (2006) that ???emissions of radionuclides to ambient air from U.S. DOE facilities shall not exceed those amounts that would cause any member of the public to receive in any year an effective dose equivalent exceeding 10 mrem/year.??? To meet the requirement for monitoring only, ???radionuclide releases that would result in an effective dose of 10% of the standard shall be readily detectable and distinguishable from background.??? Thus, the hypothetical network consists of air samplers placed at residence locations that surround INL and at other locations where onsite livestock grazing takes place. Two exposure scenarios were used in this evaluation: a resident scenario and a shepherd/rancher scenario. The resident was assumed to be continuously present at their residence while the shepherd/rancher was assumed to be present 24-hours at a fixed location on the grazing allotment. Important radionuclides were identified from annual INL radionuclide National Emission Standards for Hazardous Pollutants reports. Important radionuclides were defined as those that potentially contribute 1% or greater to the annual total dose at the radionuclide National Emission Standards for Hazardous Pollutants maximally exposed individual location and include H-3, Am-241, Pu-238, Pu 239, Cs-137, Sr-90, and I-131. For this evaluation, the network performance objective was set at achieving a frequency of detection greater than or equal to 95%. Results indicated that the hypothetical network for the resident scenario met all performance objectives for H-3 and I-131 and most performance objectives for Cs-137 and Sr-90. However, all actinides failed to meet the performance objectives for most sources. The shepherd/rancher scenario showed that air samplers placed around the facilities every 22.5 degrees were very effective in detecting releases, but this arrangement is not practical or cost effective. However, it was shown that a few air samplers placed in the prevailing wind direction around each facility could achieve the performance objective of a frequency of detection greater than or equal to 95% for the shepherd/rancher scenario. The results also indicate some of the current sampler locations have little or no impact on the network frequency of detection and could be removed from the network with no appreciable deterioration of performance. Results show that with some slight modifications to the existing network (i.e., additional samplers added north and south of the Materials and Fuels Complex and ineffective samplers removed), the network would achieve performance objectives for all sources for both the resident and shepherd/rancher scenario.

【 预 览 】
附件列表
Files Size Format View
8158KB PDF download
  文献评价指标  
  下载次数:16次 浏览次数:14次