科技报告详细信息
Performance Analysis of a Modular Small-Diameter Air Distribution System
Poerschke, Andrew1  Rudd, Armin2 
[1] IBACOS, Inc., Pittsburgh, PA (United States);ABT Systems, LLC, Annville, PA (United States)
关键词: residential;    residential buildings;    building america;    ibacos;    duct;    space conditioning;   
DOI  :  10.2172/1240501
RP-ID  :  DOE/GO--102016-4751
PID  :  OSTI ID: 1240501
Others  :  Other: 7332
学科分类:能源(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space-conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to easily be brought within conditioned space via interior partition walls. Centrally locating the air handling unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives a similar amount of airflow???regardless of its position on the box. Furthermore, within a reasonable set of length restrictions each duct continues to receive similar airflow.

【 预 览 】
附件列表
Files Size Format View
2990KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:25次