科技报告详细信息
Report on the Radiation Effects Testing of the Infrared and Optical Transition Radiation Camera Systems
Holloway, Michael Andrew1 
[1]Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
关键词: BEAM MONITORING;    TRANSITION RADIATION;    X RADIATION;    CAMERAS;    OPTICAL SYSTEMS;    ELECTRONIC CIRCUITS;    RELIABILITY;    TESTING;    RADIATION EFFECTS;    WINDOWS;    LENSES;    RECOMMENDATIONS;    RADIATION PROTECTIO;   
DOI  :  10.2172/1249005
RP-ID  :  LA-UR--16-22700
PID  :  OSTI ID: 1249005
Others  :  TRN: US1601277
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
Presented in this report are the results tests performed at Argonne National Lab in collaboration with Los Alamos National Lab to assess the reliability of the critical 99Mo production facility beam monitoring diagnostics. The main components of the beam monitoring systems are two cameras that will be exposed to radiation during accelerator operation. The purpose of this test is to assess the reliability of the cameras and related optical components when exposed to operational radiation levels. Both X-ray and neutron radiation could potentially damage camera electronics as well as the optical components such as lenses and windows. This report covers results of the testing of component reliability when exposed to X-ray radiation. With the information from this study we provide recommendations for implementing protective measures for the camera systems in order to minimize the occurrence of radiation-induced failure within a ten month production run cycle.
【 预 览 】
附件列表
Files Size Format View
675KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:13次