| Technology Solutions for New and Existing Homes Case Study: Optimized Slab-on-Grade Foundation Insulation Retrofits | |
| T. Schirber  Goldberg, L.1  Mosiman, G.1  | |
| [1] NorthernSTAR Buidling American Partnership, Madison, WI (United States) | |
| 关键词: residential; residential buildings; NorthernSTAR; Building America; slab-on-grade; insulation; energy; cost; | |
| DOI : 10.2172/1256790 RP-ID : DOE/GO--102016-4727 PID : OSTI ID: 1256790 Others : Other: 7413 |
|
| 学科分类:能源(综合) | |
| 美国|英语 | |
| 来源: SciTech Connect | |
PDF
|
|
【 摘 要 】
A more accurate assessment of SOG foundation insulation energy savings than traditionally possible is now feasible. This has been enabled by advances in whole building energy simulation with 3-dimensional foundation modelling integration at each time step together with an experimental measurement of the site energy savings of SOG foundation insulation. Ten SOG insulation strategies were evaluated on a test building to identify an optimum retrofit insulation strategy in a zone 6 climate (Minneapolis, MN). The optimum insulation strategy in terms of energy savings and cost effectiveness consisted of two components: (a) R-20 XPS insulation above grade, and, (b) R-20 insulation at grade (comprising an outer layer of R-10 insulation and an interior layer of R-12 poured polyurethane insulation) tapering to R-10 XPS insulation at half the below-grade wall height (the lower half of the stem wall was uninsulated).
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 748KB |
PDF