科技报告详细信息
Solvent Hold Tank Sample Results for MCU-16-348-349-350: March 2016 Monthly Sample
Fondeur, F. F.1  Jones, D. H.1 
[1] Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)
关键词: CHEMICAL COMPOSITION;    QUANTITATIVE CHEMICAL ANALYSIS;    TANKS;    SOLVENTS;    SAMPLING;    SAVANNAH RIVER PLANT;    PERIODICITY;   
DOI  :  10.2172/1254425
RP-ID  :  SRNL-STI--2016-00265
PID  :  OSTI ID: 1254425
Others  :  TRN: US1601407
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-348-349-350), pulled on 03/30/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-348-349-350 indicated the IsoparTML concentration is above its nominal level (101%). The modifier (CS-7SB) and the TiDG concentrations are 9% and 55% below their nominal concentrations. This analysis confirms the solvent may require the addition of TiDG, and possibly of modifier. Based on the current monthly sample, the levels of TiDG, IsoparTML, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended.

【 预 览 】
附件列表
Files Size Format View
496KB PDF download
  文献评价指标  
  下载次数:20次 浏览次数:9次