Plate impact experiments on DC745U cooled to ~ -60 ?��C | |
Gustavsen, Richard L.1  Dattelbaum, Dana M.1  Bartram, Brian Douglas1  Gibson, Lloyd Lee1  Jones, Justin Daniel1  Goodbody, Austin Bernard1  | |
[1] Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Shock and Detonation Physics | |
关键词: plate impact; Hugoniot; magnetic gauging; silicone elastomers; | |
DOI : 10.2172/1304808 RP-ID : LA-UR--16-26360 PID : OSTI ID: 1304808 |
|
学科分类:材料科学(综合) | |
美国|英语 | |
来源: SciTech Connect | |
【 摘 要 】
Using gas-gun driven plate impact experiments, we have measured the US - up Hugoniot of the silicone elastomer DC745U cooled to -60 ?��C. In summary, the initial density changes from p0 (23?��C) = 1.312 ?? 0.010 g/cm3 to p0 (-60?��C) = 1.447 ?? 0.011 g/cm3. The linear US - up Hugoniot changes from US = 1.62 + 1.74up km/s at +23?��C, to US = 2.03 ?? 0.06 + (2.03 ?? 0.06) up km/s at -60?��C. DC745U, therefore is much stiffer at -60?��C than at +23?��C, probably due to the crystallization that occurs at ~ -50?��C. Caveats/deficiencies: 1) This report does not provide an adequate pedigree of the DC745U used. 2) References to unpublished room temperature shock compression data on the elastomer are inadequate. 3) The report has not been fact checked by a DC745 subject matter expert.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
1431KB | download |