CT-Derived Hounsfield Units vs Dual-Energy X-Ray Absorptiometry in Spine Surgical Candidates: Concordance, Discordance, and Clinically Actionable Thresholds
Original Articles
Akihiko Hiyama1  Daisuke Sakai1  Hiroyuki Katoh1  Masato Sato1  Masahiko Watanabe1 
[1] Department of Orthopaedic Surgery, , Isehara, Japan
关键词: hounsfield unit;    dual-energy X-ray absorptiometry;    bone mineral density;    osteoporosis screening;    computed tomography;    osteoporosis;    diagnostic concordance;   
DOI  :  10.1177/21925682261418636
 received in 2025-11-13, accepted in 2026-01-12,  发布年份 2026
来源: Sage Journals
PDF
【 摘 要 】

Study DesignRetrospective study.ObjectiveTo evaluate diagnostic concordance between CT–derived Hounsfield Units (HU) and DXA T-scores in spinal surgery candidates, and to identify factors related to discordance.MethodsWe analyzed 180 patients (mean age 72.4 ± 8.2 years) who had lumbar CT and DXA. DXA osteoporosis was defined by the lowest T-score (lumbar spine or hip) ≤ −2.5, and CT osteoporosis was defined as HU ≤ 100. Patients were classified into concordant positive (DXA+/HU+), concordant negative (DXA−/HU−), and two discordant groups (DXA+/HU−, DXA−/HU+). Analyses included correlation, ROC analysis, and comparisons of age, BMI, sex, and the DXA site yielding the lowest T-score.ResultsHU and T-scores showed correlation (Spearman’s ρ = 0.467, P < 0.001) with discrimination (AUC = 0.700; 95% CI 0.614-0.781). Concordance was 72.2% (130/180; DXA−/HU− = 94, DXA+/HU+ = 36); discordance was 27.8% (50/180; DXA+/HU− = 24; DXA−/HU+ = 26). DXA+/HU + patients were older than DXA−/HU− (75.9 ± 6.5 vs 71.1 ± 9.1 years; P = 0.003), and both DXA + groups had lower BMI (22.9 ± 3.8 and 22.7 ± 4.8 vs 24.8 ± 3.8 kg/m2; P = 0.009 and 0.029). The HU 100-150 “gray zone” was not associated with discordance (23.3% vs 30.8%, P = 0.311).ConclusionsHU values show moderate agreement with DXA and are useful for opportunistic screening. Given ∼27% discordance—especially in older or lower-BMI patients—HU should be interpreted alongside DXA for comprehensive assessment.

【 授权许可】

CC BY-NC-ND   
© The Author(s) 2026

【 预 览 】
附件列表
Files Size Format View
RO202609290005971ZK.pdf 1272KB PDF download
MDAR checklist 89KB Other download
Fig. 1 1495KB Image download
Figure 5—figure supplement 1—source data 2. 8375KB Other download
Table 4 85KB Table download
【 图 表 】

Fig. 1

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  文献评价指标  
  下载次数:2次 浏览次数:0次