期刊论文详细信息
Scientific Reports 卷:16
Physics-informed learning–based fault-tolerant control for robust wireless power transfer in electric vehicles
Article
Muhammad Haris Saleem1  Arslan Ahmed Amin1  Turki Alsuwian2 
[1] Department of Electrical Engineering, College of Engineering, Najran University, 11001, Najran, Saudi Arabia
[2] Department of Electrical Engineering, FAST National University of Computer and Emerging Sciences, CFD Campus, 35400, Chiniot, Pakistan
关键词: Wireless power transfer;    Fault-tolerant control;    Active fault-tolerant control;    Electric vehicle;    Physics-informed neural network;   
DOI  :  10.1038/s41598-026-57870-y
 received in 2026-03-20, accepted in 2026-06-10,  发布年份 2026
来源: Springer
PDF
【 摘 要 】

Wireless Power Transfer-based electric vehicles (EVs) emerge as a promising technology that can drastically reduce carbon emissions worldwide. Conventional ICE-based transportation has led to a significant increase in greenhouse gas emissions and exacerbated climate change. On the contrary, WPT-based EVs can offer extended range, contactless charging, enhanced safety, and reduced vehicle costs. However, the complex design of WPT is vulnerable to power converter failure and coil misalignment. These faults can significantly deteriorate the performance of the WPT-based EVs. A power converter failure can degrade WPT performance, and this paper introduces redundant switches to ensure smooth vehicle operation. This paper presents a Physics-informed Neural Network (PINN) that incorporates physical laws to observe signals from power converters and control the Active Fault-Tolerant Controller (AFTC). The AFTCS consists of the FDI block, which is responsible for detecting and isolating faults in real time. The PINN-based observer system monitors the signal in real time. The results clearly illustrate that the proposed framework provides accurate current tracking and ensures the residual signal remains in the threshold even in parameter variations and achieves a reduced settling time of 0.22s. Furthermore, the steady-state error is reduced to 0.3 A, outperforming the other control methods and ensuring the stability of the system in the event of faults. Thus, a PINN-based FTC is introduced to ensure the resilience and reliable operation of WPT-based EVs in case of power converter failure and coil misalignment.

【 授权许可】

CC BY-NC-ND   
© The Author(s) 2026

【 预 览 】
附件列表
Files Size Format View
RO202609150001277ZK.pdf 6122KB PDF download
Figure 7. Viability of eukaryotic cells (MDA-MB-231) in 2D culture. 31KB Image download
Fig. 2 632KB Image download
Supporting File 3 11KB Other download
Fig. 3 408KB Image download
Supporting File 14264KB Other download
Fig. 7 571KB Image download
TABLE 3 5KB Table download
MediaObjects/13690_2026_1939_MOESM1_ESM.docx 276KB Other download
Supporting File 7 14KB Other download
TABLE 1 2KB Table download
Fig. 22 266KB Image download
TABLE 1 3KB Table download
【 图 表 】

Fig. 22

Fig. 7

Fig. 3

Fig. 2

Figure 7. Viability of eukaryotic cells (MDA-MB-231) in 2D culture.

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  • [37]
  文献评价指标  
  下载次数:2次 浏览次数:0次