期刊论文详细信息
Radiation Oncology 卷:21
How reliable is deep inspiration breath hold at CT simulation? Clinical impact of surface-guided breathing training in breast cancer radiotherapy
Research
Lou Dietrich1,2  Niklas Lackner1,2  Andre Karius1,2  Johann Brand1,2  Rafael Lobao1,2  Aliheydar Huseynli1,2  Oliver J. Ott1,2  Stefanie Corradini1,2  Rainer Fietkau1,2  Christoph Bert1,2  Maya Shariff1,2 
[1] Comprehensive Cancer Center Erlangen-EMN (CCC ER-EMN), Erlangen, Germany
[2] Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich- Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
关键词: Surface guided radiation therapy;    DIBH;    CT simulation;    Dose evaluation;   
DOI  :  10.1186/s13014-026-02920-y
 received in 2026-03-20, accepted in 2026-08-28,  发布年份 2026
来源: Springer
【 摘 要 】

PurposeDeep inspiration breath hold (DIBH) is widely used to reduce cardiac dose in left-sided breast radiotherapy. However, the reliability of DIBH at CT simulation, has not been systematically evaluated despite the importance of CT simulation as the basis for treatment planning. We investigated the clinical impact of surface-guided breathing training on DIBH reliability and cardiac dose sparing.MethodsIn this retrospective cohort study, 115 breast cancer patients undergoing DIBH CT simulation were analyzed before and after implementation of surface-guided breathing training using an SGRT system. DIBH performance was quantified by partial lung volume increase (PLVI) and breath-hold variability. Correlations between external surface motion and internal DIBH depth were assessed. Cardiac dose metrics were compared, with a subgroup analysis for patients receiving lymphatic drainage area (LDA) irradiation.ResultsPrior to training, insufficient DIBH CTs—including negative PLVI cases—were observed. After training implementation, all CT scans were acquired in intended breath-hold states, eliminating insufficient DIBH acquisitions. Mean PLVI increased by ~ 9%, and breath-hold variability decreased by ~ 26%. Sternum motion correlated most strongly with PLVI, with multiregion surface monitoring yielding the highest internal correlation. These improvements were reflected in significant reductions in cardiac dose, particularly in the LDA subgroup, with selected heart dose metrics reduced up to 96%, while maintaining target coverage.ConclusionsDIBH at CT simulation with surface-guided breathing training proves to be reliable. The training prevents planning CTs in wrong breathing states and thus enables clinically meaningful cardiac dose reduction in breast radiotherapy.

【 授权许可】

CC BY   
© The Author(s) 2026

附件列表
Files Size Format View
Supporting File 4 44563KB Other download
Supporting file 39889KB Other download
Algorithm 1 33KB Image download
MediaObjects/40066_2026_633_MOESM1_ESM.docx 120KB Other download
Fig. 2 1021KB Image download
Fig. 7 26KB Image download
【 图 表 】

Fig. 7

Fig. 2

Algorithm 1

【 参考文献 】
  • [1]
  • [2]
  • [3]
  • [4]
  • [5]
  • [6]
  • [7]
  • [8]
  • [9]
  • [10]
  • [11]
  • [12]
  • [13]
  • [14]
  • [15]
  • [16]
  • [17]
  • [18]
  • [19]
  • [20]
  • [21]
  • [22]
  • [23]
  • [24]
  • [25]
  • [26]
  • [27]
  • [28]
  • [29]
  • [30]
  • [31]
  • [32]
  • [33]
  • [34]
  • [35]
  • [36]
  文献评价指标  
  下载次数:0次 浏览次数:0次