Analytical study of the effects of soft tissue artefacts on functional techniques to define axes of rotation
Article
De Rosario, Helios1,2  Page, Alvaro1,2  Besa, Antonio3 
[1] Univ Politecn Valencia, Inst Biomecan Valencia, Edificio 9C,Camino Vera S-N, E-46022 Valencia, Spain
[2] CIBER Bioingn Biomat & Nanomed CIBER BBN, Valencia, Spain
[3] Univ Politecn Valencia, Ctr Invest Ingn Mecan, Valencia, Spain
关键词: Functional calibration;    Axis of rotation;    Soft tissue artefacts;    Geometric fitting;    Finite helical axis;    Knee joint;   
DOI  :  10.1016/j.jbiomech.2017.01.046
来源: Elsevier
PDF
【 摘 要 】

The accurate location of the main axes of rotation (AoR) is a crucial step in many applications of human movement analysis. There are different formal methods to determine the direction and position of the AoR, whose performance varies across studies, depending on the pose and the source of errors. Most methods are based on minimizing squared differences between observed and modelled marker positions or rigid motion parameters, implicitly assuming independent and uncorrelated errors, but the largest error usually results from soft tissue artefacts (STA), which do not have such statistical properties and are not effectively cancelled out by such methods. However, with adequate methods it is possible to assume that STA only account for a small fraction of the observed motion and to obtain explicit formulas through differential analysis that relate STA components to the resulting errors in AoR parameters. In this paper such formulas are derived for three different functional calibration techniques (Geometric Fitting, mean Finite Helical Axis, and SARA), to explain why each technique behaves differently from the others, and to propose strategies to compensate for those errors. These techniques were tested with published data from a sit-to-stand activity, where the true axis was defined using bi-planar fluoroscopy. All the methods were able to estimate the direction of the AoR with an error of less than 5 degrees whereas there were errors in the location of the axis of 30-40 mm. Such location errors could be reduced to less than 17 mm by the methods based on equations that use rigid motion parameters (mean Finite Helical Axis, SARA) when the translation component was calculated using the three markers nearest to the axis. (C) 2017 Elsevier Ltd. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_jbiomech_2017_01_046.pdf 481KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:1次