期刊论文详细信息
JOURNAL OF BIOMECHANICS 卷:121
Reliability of measures to characterize lumbar movement patterns, in repeated seated reaching, in a mixed group of participants with and without low-back pain: A test-retest, within- and between session
Article
Wildenbeest, Meta H.1,2  Kiers, Henri1  Tuijt, Matthijs1  van Dieen, Jaap H.2 
[1] HU Univ Appl Sci, Inst Human Movement Studies, Postbus 12011, NL-3501 AA Utrecht, Netherlands
[2] Vrije Univ Amsterdam, Dept Human Movement Sci, Amsterdam Movement Sci, NL-1081 BT Amsterdam, Netherlands
关键词: Test-retest;    Spinal control;    Reliability;    Stability;    Variability;   
DOI  :  10.1016/j.jbiomech.2021.110435
来源: Elsevier
PDF
【 摘 要 】

Literature highlights the need for research on changes in lumbar movement patterns, as potential mechanisms underlying the persistence of low-back pain. Variability and local dynamic stability are frequently used to characterize movement patterns. In view of a lack of information on reliability of these measures, we determined their within-and between-session reliability in repeated seated reaching. Thirty-six participants (21 healthy, 15 LBP) executed three trials of repeated seated reaching on two days. An optical motion capture system recorded positions of cluster markers, located on the spinous pro-cesses of S1 and T8. Movement patterns were characterized by the spatial variability (meanSD) of the lumbar Euler angles: flexion-extension, lateral bending, axial rotation, temporal variability (CyclSD) and local dynamic stability (LDE). Reliability was evaluated using intraclass correlation coefficients (ICC), coefficients of variation (CV) and Bland-Altman plots. Sufficient reliability was defined as an ICC >= 0.5 and a CV < 20%. To determine the effect of number of repetitions on reliability, analyses were performed for the first 10, 20, 30, and 40 repetitions of each time series. MeanSD, CyclSD, and the LDE had moderate within-session reliability; meanSD: ICC = 0.60-0.73 (CV = 14-17%); CyclSD: ICC = 0.68 (CV = 17%); LDE: ICC = 0.62 (CV = 5%). Between-session reliability was some-what lower; meanSD: ICC = 0.44-0.73 (CV = 17-19%); CyclSD: ICC = 0.45-0.56 (CV = 19-22%); LDE: ICC = 0.25-0.54 (CV = 5-6%). MeanSD, CyclSD and the LDE are sufficiently reliable to assess lumbar movement patterns in single -session experiments, and at best sufficiently reliable in multi-session experiments. Within-session, a pla-teau in reliability appears to be reached at 40 repetitions for meanSD (flexion-extension), meanSD (axial -rotation) and CyclSD. (c) 2021 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_jbiomech_2021_110435.pdf 1525KB PDF download
  文献评价指标  