期刊论文详细信息
JOURNAL OF BIOMECHANICS 卷:126
Applicability analysis to evaluate credibility of an in silico thrombectomy procedure
Article
Luraghi, Giulia1  Bridio, Sara1  Miller, Claire2  Hoekstra, Alfons2  Matas, Jose Felix Rodriguez1  Migliavacca, Francesco1 
[1] Politecn Milan, Dept Chem Mat & Chem Engn, Lab Biol Struct Mech LaBS, Milan, Italy
[2] Univ Amsterdam, Fac Sci, Informat Inst, Computat Sci Lab, Amsterdam, Netherlands
关键词: Applicability analysis;    Model credibility;    Thrombectomy;    In silico clinical trial;    Finite element method;   
DOI  :  10.1016/j.jbiomech.2021.110631
来源: Elsevier
PDF
【 摘 要 】

Intra-arterial thrombectomy is a minimally invasive procedure in which an obstructing thrombus (clot) is removed using a minimally-invasive device: a stent-retriever. The stent-retriever is first deployed, and then the thrombus is removed during stent-retriever retraction. This procedure can be simulated using a detailed computational model. However, to be useful for an in silico trial in a clinical setting, model credibility should be demonstrated. The aim of this work is to apply a credibility process for the validation phases to the thrombectomy procedure in order to deem it credible for use in an in silico trial. Validation evidence is proposed for the identified context of use and then used to build credibility to the numerical model. Applicability of the proposed model is justified and assessed using a rigorous step-by-step method based on the ASME V&V40 protocol.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_jbiomech_2021_110631.pdf 3573KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:0次