期刊论文详细信息
JOURNAL OF ALLOYS AND COMPOUNDS 卷:731
Real time resistance monitoring during sintering of silver paste
Article
Xu, Di Erick1  Kim, Jang Baeg1,2  Hook, Michael David1  Jung, Jae Pil2  Mayer, Michael1 
[1] Univ Waterloo, Microjoining Lab, Ctr Adv Mat Joining, Dept Mech & Mechatron Engn, Waterloo, ON N2L 3G1, Canada
[2] Univ Seoul, Microjoining & Semicond Packaging Lab, Dept Mat Sci & Engn, 90 JunNong Dong, Seoul 130743, South Korea
关键词: Silver sintering paste;    Non-destructive signals;    Sintering process;    Real time monitoring;   
DOI  :  10.1016/j.jallcom.2017.10.077
来源: Elsevier
PDF
【 摘 要 】

Real time resistance monitoring technology is used to study the silver sintering process. Signals of joint resistance show events such as resistance increase to >10 G Omega, abrupt resistance drop from >10 G Omega to <1 k Omega, and gradual resistance drop to < 1 m Omega. Based on cross-sectioning of samples at various stages of sintering and differential scanning calorimetry (DSC), we propose a correlation between resistance signal and solvent evaporation, capping agent degradation, and silver sintering. We identified distinct clusters of sintered silver of samples removed from the oven when the resistance drops to similar to 2.94 Omega. (C) 2017 Elsevier B.V. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_jallcom_2017_10_077.pdf 4469KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:0次