期刊论文详细信息
JACC-CARDIOVASCULAR IMAGING 卷:6
Real-Time Integration of MDCT-Derived Coronary Anatomy and Epicardial Fat Impact on Epicardial Electroanatomic Mapping and Ablation for Ventricular Arrhythmias
Article
van Taxis, Carine F. van Huls1  Wijnmaalen, Adrianus P.1  Piers, Sebastiaan R.1  van der Geest, Rob J.2  Schalij, Martin J.1  Zeppenfeld, Katja1 
[1] Leiden Univ, Dept Cardiol, Med Ctr, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ, Div Image Proc, Med Ctr, NL-2300 RC Leiden, Netherlands
关键词: epicardial ablation;    epicardial fat;    MDCT integration;    ventricular arrhythmias;   
DOI  :  10.1016/j.jcmg.2012.05.016
来源: Elsevier
PDF
【 摘 要 】

OBJECTIVES This study aimed to evaluate the feasibility and accuracy of real-time integration of multidetector computed tomography (MDCT) derived coronary anatomy and epicardial fat distribution and its impact on electroanatomical mapping and ablation. BACKGROUND Epicardial catheter ablation for ventricular arrhythmias (VA) is an important therapeutic option in patients after endocardial ablation failure. However, epicardial mapping and ablation are limited by the presence of coronary arteries and epicardial fat. METHODS Twenty-eight patients (21 male, age 59 +/- 16 years) underwent combined endo-epicardial electroanatomical mapping. Prior to the procedure, MDCT derived coronary anatomy and epicardial fat meshes were loaded into the mapping system (CARTO XP, Biosense Webster Inc, Diamond Bar, California). Real-time registration of MDCT data was performed after endocardial mapping. The distance between epicardial ablation sites and coronary arteries was assessed by registered MDCT and angiography. After the procedure, mapping and ablation points were superimposed on the MDCT using a reversed registration matrix for head-to-head comparison of mapping data and corresponding fat thickness. RESULTS Image registration was successful and accurate in all patients (position error 2.8 +/- 1.3 mm). At sites without evidence for scar, epicardial bipolar voltage decreased significantly (p < 0.001) with increasing fat thickness. Forty-six VA were targeted; 25 (54%) were abolished by catheter ablation, in 21 (46%) ablation failed. In 5 VA no target site was identified and in 3 VA adhesions prevented mapping. In 2 VA ablation was withheld due to His-bundle vicinity and in 7 VA due to proximity of coronary arteries. In 4 VA catheter ablation was ineffective. At ineffective ablation sites epicardial fat was significantly thicker compared to successful sites (16.9 +/- 6.8mm [range 7.3 to 22.2 mm] and 1.5 +/- 2.1 mm [range 0.0 to 6.1 mm], p = 0.002). CONCLUSIONS Real-time image integration of pre-acquired MDCT information is feasible and accurate. Epicardial fat >7 mm and the presence of coronary arteries are important reasons for epicardial ablation failure. Visualization of fat thickness during the procedure may facilitate interpretation of bipolar electrograms and identification of ineffective ablation sites. (J Am Coll Cardiol Img 2013;6:42-52) (C) 2013 by the American College of Cardiology Foundation

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_jcmg_2012_05_016.pdf 1805KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:0次