期刊论文详细信息
INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES 卷:190
Finite element simulation of human trachea: Normal vs. surgically treated and scaffold implanted cases
Article
Safshekan, Farzaneh1  Tafazzoli-Shadpour, Mohammad2  Abdouss, Majid3  Shadmehr, Mohammad B.4  Ghorbani, Fariba4 
[1] Ahrar Inst Technol & Higher Educ, Dept Mech Engn, Rasht, Iran
[2] Amirkabir Univ Technol, Fac Biomed Engn, Tehran, Iran
[3] Amirkabir Univ Technol, Chem Dept, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Masih Daneshvari Hosp, Tracheal Dis Res Ctr, NRITLD, Shahid Bahonar Ave, Tehran, Iran
关键词: Trachea;    Airway mechanics;    Finite element;    Surgery;    Scaffold;   
DOI  :  10.1016/j.ijsolstr.2019.10.021
来源: Elsevier
PDF
【 摘 要 】

Trachea experiences mechanical loads under physiological conditions. Surgery and tissue engineering change its mechanical conditions and may cause remodeling or damage. Here, we mechanically simulated one healthy trachea (from a 53-year-old brain-dead man) and as two examples, evaluated the impacts of surgery and scaffold implantation. Before patient's death, CT-scanning was performed at two respiratory pressures (0 and +40 cm H2O for constructing 3D tracheal geometry at zero-stress state and model validation, respectively). After harvesting trachea, MRI, mechanical testing and hyperelastic modeling of tracheal tissues (cartilage, smooth muscle, and connective tissue) were performed. We simulated tracheal deformation and stress distribution under three conditions, including normal, 30%-resection of tracheal length and anastomosis (surgery) or its substitution with a cylindrical scaffold. In all models, the greatest stresses were produced in cartilaginous rings. Surgery-related extension reduced the physiologic cross-sectional deformability and increased stress levels in response to respiratory pressures, compared to normal trachea. For instance, maximum von-Mises stress in normal and operated trachea reached 355 kPa and 3.228 MPa, respectively. Scaffold was less deformable than normal trachea, though stress levels in both models were relatively close. This study provides an insight into the mechanics of human trachea and the impacts of surgery or scaffold implantation. (C) 2019 Elsevier Ltd. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_ijsolstr_2019_10_021.pdf 2275KB PDF download
  文献评价指标  
  下载次数:4次 浏览次数:0次