期刊论文详细信息
JOURNAL OF COLLOID AND INTERFACE SCIENCE 卷:331
Instability analysis of torsional MEMS/NEMS actuators under capillary force
Article
Guo, Jian-Gang2  Zhou, Li-Jun3  Zhao, Ya-Pu1 
[1] Chinese Acad Sci, Inst Mech, State Key Lab Nonlinear Mech, Beijing 100190, Peoples R China
[2] Tianjin Univ, Dept Mech, Tianjin 300072, Peoples R China
[3] Tianjin Univ Technol & Educ, Dept Mech Engn, Tianjin 300222, Peoples R China
关键词: Torsional NEMS actuator;    Capillary force;    Instability;    Bifurcation;   
DOI  :  10.1016/j.jcis.2008.11.069
来源: Elsevier
PDF
【 摘 要 】

The static and dynamic instabilities of a torsional MEMS/NEMS actuator caused by capillary effects are studied, respectively. An instability number, eta, is defined, and the critical gap distance, g(cr), between the mainplate and the substrate is derived. According to the values of eta and g, the instability criteria of the actuator are presented. The dimensionless motion equation of the MEMS/NEMS torsional actuator is derived when it makes nonlinear oscillation under capillary force. The qualitative analysis of the nonlinear equation is made, and the phase portraits are presented on the phase plane. In addition, the bifurcation phenomena in the system are also analyzed. (C) 2008 Elsevier Inc. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_jcis_2008_11_069.pdf 492KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:0次