| JOURNAL OF HAZARDOUS MATERIALS | 卷:414 |
| Comparison and uncertainty evaluation of two centrifugal separators for microplastic sampling | |
| Article | |
| Hildebrandt, Lars1,2  Zimmermann, Tristan1  Primpke, Sebastian3  Fischer, Dieter4  Gerdts, Gunnar3  Proefrock, Daniel1  | |
| [1] Helmholtz Zentrum Geesthacht, Dept Marine Bioanalyt Chem, Ctr Mat & Coastal Res, Geesthacht, Germany | |
| [2] Univ Hamburg, Dept Chem Inorgan & Appl Chem, Hamburg, Germany | |
| [3] Alfred Wegener Inst, Helmholtz Ctr Polar & Marine Res, Dept Microbial Ecol, Biol Anstalt Helgoland, Helgoland, Germany | |
| [4] Leibniz Inst Polymer Res Dresden, Dept Analyt, Grp Microplast, Dresden, Germany | |
| 关键词: Hydrocyclone; Continuous flow centrifugation; Measurement uncertainty; FTIR Imaging; Raman Imaging; QA; QC; Microplastic monitoring; Estuarine microplastic pollution; | |
| DOI : 10.1016/j.jhazmat.2021.125482 | |
| 来源: Elsevier | |
PDF
|
|
【 摘 要 】
For commonly applied microplastic sampling approaches based on filtration, high throughput and no sizediscrimination are conflicting goals. Therefore, we propose two efficient centrifugal separators for small microplastic sampling, namely the utilization of a hydrocyclone as well as a continuous flow centrifuge. Thorough method optimization was followed by application in an extensive sampling study to investigate the separators' retention behavior for particulate plastics from estuarine waters. Microplastic concentrations ranged from 193 to 2072 particles m-3. The most dominant identified polymer types were polypropylene, acrylates, polyvinyl chloride and polyethylene. More than 95% of particles were < 100 & micro;m. For the first time in microplastic research, an expanded uncertainty was calculated according to the Guide to the expression of Uncertainty in Measurement (JCGM 100:2008). Bottom-up uncertainty evaluation revealed the different sampling methods (- 44%), sample replicates (- 26%) and the different detection techniques (16%) as the major sources of uncertainty. Depending on the number of particles detected in the samples, the relative expanded uncertainty (Urel (k = 2)) ranged from 24% up to > 200% underpinning tremendous importance of sound uncertainty evaluation. Our results indicate that scientist should rethink many observed patterns in the literature due to being insignificant and herewith not real.