期刊论文详细信息
JOURNAL OF HYDROLOGY 卷:530
Resistivity and self-potential tomography applied to groundwater remediation and contaminant plumes: Sandbox and field experiments
Article
Mao, D.1  Revil, A.1,2  Hort, R. D.3  Munakata-Marr, J.3  Atekwana, E. A.4  Kulessa, B.5 
[1] Colorado Sch Mines, Dept Geophys, Green Ctr, Golden, CO 80401 USA
[2] Univ Savoie Mt Blanc, ISTerre, CNRS, UMR 5275, F-73376 Le Bourget Du Lac, France
[3] Colorado Sch Mines, Dept Civil & Env Engn, Golden, CO 80401 USA
[4] Oklahoma State Univ, Boone Pickens Sch Geol, Stillwater, OK 74075 USA
[5] Swansea Univ, Coll Sci, Swansea SA2 8PP, W Glam, Wales
关键词: Electrical resistivity;    Self-potential;    Tomography;    Remediation;    Contaminant plume;    Hydrogeophysics;   
DOI  :  10.1016/j.jhydrol.2015.09.031
来源: Elsevier
PDF
【 摘 要 】

Geophysical methods can be used to remotely characterize contaminated sites and monitor in situ enhanced remediation processes. We have conducted one sandbox experiment and one contaminated field investigation to show the robustness of electrical resistivity tomography and self-potential (SP) tomography for these applications. In the sandbox experiment, we injected permanganate in a trichloroethylene (TCE)-contaminated environment under a constant hydraulic gradient. Inverted resistivity tomograms are able to track the evolution of the permanganate plume in agreement with visual observations made on the side of the tank. Self-potential measurements were also performed at the surface of the sandbox using non-polarizing Ag-AgCl electrodes. These data were inverted to obtain the source density distribution with and without the resistivity information. A compact horizontal dipole source located at the front of the plume was obtained from the inversion of these self-potential data. This current dipole may be related to the redox reaction occurring between TCE and permanganate and the strong concentration gradient at the front of the plume. We demonstrate that time-lapse self-potential signals can be used to track the kinetics of an advecting oxidizer plume with acceptable accuracy and, if needed, in real time, but are unable to completely resolve the shape of the plume. In the field investigation, a 3D resistivity tomography is used to characterize an organic contaminant plume (resistive domain) and an overlying zone of solid waste materials (conductive domain). After removing the influence of the streaming potential, the identified source current density had a magnitude of 0.5 A m(-2). The strong source current density may be attributed to charge movement between the neighboring zones that encourage abiotic and microbially enhanced reduction and oxidation reactions. In both cases, the self-potential source current density is located in the area of strong resistivity gradient (C) 2015 Elsevier B.V. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_jhydrol_2015_09_031.pdf 1728KB PDF download