期刊论文详细信息
JOURNAL OF HYDROLOGY 卷:530
A comparison of thermal infrared to fiber-optic distributed temperature sensing for evaluation of groundwater discharge to surface water
Article
Hare, Danielle K.1,2  Briggs, Martin A.2  Rosenberry, Donald O.3  Boutt, David F.1  Lane, John W.2 
[1] Univ Massachusetts, Dept Geosci, Amherst, MA 01003 USA
[2] US Geol Survey, Off Groundwater, Branch Geophys, Storrs, CT 06269 USA
[3] US Geol Survey, Natl Res Program, Cent Branch, Lakewood, CO 80225 USA
关键词: Groundwater seepage;    Heat tracing;    Streams;    Infrared;    Distributed temperature sensing;    Groundwater/surface water interactions;   
DOI  :  10.1016/j.jhydrol.2015.09.059
来源: Elsevier
PDF
【 摘 要 】

Groundwater has a predictable thermal signature that can be used to locate discrete zones of discharge to surface water. As climate warms, surface water with strong groundwater influence will provide habitat stability and refuge for thermally stressed aquatic species, and is therefore critical to locate and protect. Alternatively, these discrete seepage locations may serve as potential point sources of contaminants from polluted aquifers. This study compares two increasingly common heat tracing methods to locate discrete groundwater discharge: direct-contact measurements made with fiber-optic distributed temperature sensing (FO-DTS) and remote sensing measurements collected with thermal infrared (TIR) cameras. FO-DTS is used to make high spatial resolution (typically m) thermal measurements through time within the water column using temperature-sensitive cables. The spatial temporal data can be analyzed with statistical measures to reveal zones of groundwater influence, however, the personnel requirements, time to install, and time to georeference the cables can be burdensome, and the control units need constant calibration. In contrast, TIR data collection, either from handheld, airborne, or satellite platforms, can quickly capture point-in-time evaluations of groundwater seepage zones across large scales. However the remote nature of TIR measurements means they can be adversely influenced by a number of environmental and physical factors, and the measurements are limited to the surface skin temperature of water features. We present case studies from a range of lentic to lotic aquatic systems to identify capabilities and limitations of both technologies and highlight situations in which one or the other might be a better instrument choice for locating groundwater discharge. FO-DTS performs well in all systems across seasons, but data collection was limited spatially by practical considerations of cable installation. TIR is found to consistently locate groundwater seepage zones above and along the streambank, but submerged seepage zones are only well identified in shallow systems (e.g. <0.5 m depth) with moderate flow. Winter data collection, when groundwater is relatively warm and buoyant, increases the water surface expression of discharge zones in shallow systems. (C) 2015 Elsevier B.V. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_jhydrol_2015_09_059.pdf 3957KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:0次