In-situ, non-destructive acoustic characterization of solid state electrolyte cells
Article
Schmidt, Robert D.1  Sakamoto, Jeffrey1 
[1] Univ Michigan, Dept Mech Engn, Ann Arbor, MI 48105 USA
关键词: Acoustic;    Elastic moduli;    Microcracks;    Dendrite;   
DOI  :  10.1016/j.jpowsour.2016.05.062
来源: Elsevier
PDF
【 摘 要 】

Solid-state electrolytes such as cubic Li6.25Al0.25La3Zr2O12 (LLZO) can enable solid-state batteries, metallic lithium anodes and higher voltage cathodes. However, the stability of cubic LLZO is affected by current density. In beta alumina solid electrolyte, microstructural failure was caused by Na dendrite penetration, and was shown to be a function of the fracture toughness, K-IC. The relationship between dendrite penetration and K-IC indicates electronic failure is related to creation of microstructural damage, and the microstructural damage may be used as an indicator of imminent electronic failure. To monitor micro structural damage during cycling, we developed a non-invasive, in-situ cell monitoring apparatus to help to correlate mechanical stability with Li-ion current density in LLZO. A pulse-echo transducer was integrated into all solid-state Li-LLZO-Li cells. The capability enables the characterization of microscopic inhomogeneities through the careful measurement of changes to the elastic moduli. The elastic moduli and fracture toughness have been previously reported for dense (>99%) specimens, but monitoring of the relative change in moduli during cycling has not been explored. In this study, an acoustic monitoring method is presented to monitor LLZO specimens during cycling. (C) 2016 Elsevier B.V. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_jpowsour_2016_05_062.pdf 1169KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:0次