| NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS | 卷:204 |
| Transverse emittance investigation of the ISOLDE target-ion sources | |
| Article; Proceedings Paper | |
| Wenander, F ; Lettry, J ; Lindroos, M | |
| 关键词: emittance; ion sources; ISOL system; | |
| DOI : 10.1016/S0168-583X(02)01922-5 | |
| 来源: Elsevier | |
PDF
|
|
【 摘 要 】
In order to produce target-ion sources allowing for a high isotopic resolution in the separator, CERN/ISOLDE (isotope separator on-line) has purchased a commercial emittance meter, capable of measuring transverse phase-space emittances, for ion-beam intensities down, to approximately I nA. It was installed at the ISOLDE off-line separator where targets are tested with respect to material purity and the ion-source efficiencies are determined. Now, also the emittance and brightness are measured for different stable elements. An extensive programme has been launched aiming at a complete survey of the emittance dependence on the various ion-source parameters. Results from the measurements on the different ISOLDE ion-source types, with associated analysis, are presented. (C) 2002 Elsevier Science B.V. All rights reserved.
【 授权许可】
Free
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 10_1016_S0168-583X(02)01922-5.pdf | 142KB |
PDF