| TALANTA | 卷:98 |
| Detection of trace levels of lead in aqueous liquids using extractive electrospray ionization tandem mass spectrometry | |
| Article | |
| Liu, Chunxiao2  Zhang, Xinglei1  Xiao, Saijin1  Jia, Bin1  Cui, Shasha1,3  Shi, Jianbo2  Xu, Ning1  Xie, Xi4  Gu, Haiwei1  Chen, Huanwen1  | |
| [1] E China Inst Technol, Jiangxi Key Lab Mass Spectrometry & Instrumentat, Nanchang 330013, Jiangxi, Peoples R China | |
| [2] Chinese Acad Sci, State Key Lab Environm Chem & Ecotoxicol, Ecoenvironm Sci Res Ctr, Beijing 100085, Peoples R China | |
| [3] Beijing Entry Exit Inspect & Quarantine Bur, Beijing 100026, Peoples R China | |
| [4] ACCA21, Beijing 100038, Peoples R China | |
| 关键词: Extractive electrospray ionization; Ambient mass spectrometry; Tandem mass spectrometry; Lead; Beverage; | |
| DOI : 10.1016/j.talanta.2012.06.048 | |
| 来源: Elsevier | |
PDF
|
|
【 摘 要 】
A sensitive approach, based on semi-quantitative measurement of the characteristic fragments in multistage extractive electrospray ionization mass spectrometry (EESI-MSn), was developed for fast detection of trace levels of lead in aqueous liquids including mineral water, lake water, tap water, energy drinks, soft drinks, beer, orange juice, and tea. A disodium ethylene-diamine-tetraacetic acid (EDTA) aqueous solution was electrosprayed to produce negatively charged primary ions which then intersected the neutral sample plume to generate anions of EDTA-Pb(II) complexes. The charged EDTA-Pb(II) complexes were characterized with multistage collision induced dissociation (CID) experiments. The limit of detection (LOD) using EESI-MS3 was estimated to be at the level of 10(-13) g/mL for directly detecting lead in many of these samples. The linear dynamic range was higher than 2 orders of magnitude. A single sample analysis could be completed within 2 min with reasonable semi-quantitative performance, e.g., relative standard deviations (RSDs) for deionized water were 4.6-7.6% during 5 experimental runs (each of them had 10 repeated measurements). Coca-cola and Huiyuan orange juice, representative beverage samples with complex matrices, generated recovery rates of 91.5% and 129%, respectively. Our experimental data demonstrated that EESI-MS is a useful tool for the fast detection of lead in various solutions, and EESI-MS showed promises for fast screening of lead-contaminated aqueous liquid samples. (C) 2012 Elsevier B.V. All rights reserved,
【 授权许可】
Free
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 10_1016_j_talanta_2012_06_048.pdf | 459KB |
PDF