期刊论文详细信息
TALANTA 卷:174
Multiplexed analysis combining distinctly-sized CdTe-MPA quantum dots and chemometrics for multiple mutually interfering analyte determination
Article
Bittar, Dayana B.1  Ribeiro, David S. M.2  Pascoa, Ricardo N. M. J.2  Soares, Jose X.2  Rodrigues, S. Sofia M.2  Castro, Rafael C.2  Pezza, Leonardo1  Pezza, Helena R.1  Santos, Joao L. M.2 
[1] Univ Estadual Paulista, UNESP, Inst Quim, R Prof Francisco Degni 55,POB 355, BR-14800900 Araraquara, SP, Brazil
[2] Univ Porto, Fac Pharm, Lab Appl Chem, LAQV,REQUIMTE,Dept Chem Sci, Rua Jorge Viterbo Ferreira 228, P-4050313 Oporto, Portugal
关键词: CdTe quantum dots;    Heavy metals;    Multiplexing;    Chemometrics;    Fluorescence;    Multiparametric analysis;   
DOI  :  10.1016/j.talanta.2017.06.071
来源: Elsevier
PDF
【 摘 要 】

Semiconductor quantum dots (QDs) have demonstrated a great potential as fluorescent probes for heavy metals monitoring. However, their great reactivity, whose tunability could be difficult to attain, could impair selectivity yielding analytical results with poor accuracy. In this work, the combination in the same analysis of multiple QDs, each with a particular ability to interact with the analyte, assured a multi-point detection that was not only exploited for a more precise analyte discrimination but also for the simultaneous discrimination of multiple mutually interfering species, in the same sample. Three different MPA-CdTe QDs (2.5, 3.0 and 3.8 nm) with a good size distribution, confirmed by the FWHM values of 48.6, 55.4 and 80.8 nm, respectively, were used. Principal component analysis (PCA) and partial least squares regression (PLS) were used for fluorescence data analysis. Mixtures of two MPA-CdTe QDs, emitting at different wavelength namely 549/566, 549/634 and 566/ 634 nm were assayed. The 549/634 nm emitting QDs mixture provided the best results for the discrimination of distinct ions on binary and ternary mixtures. The obtained RMSECV and R2CV values for the binary mixture were good, namely, from 0.01 to 0.08 mg L-1 and from 0.74 to 0.89, respectively. Regarding the ternary mixture the RMSECV and (RCV)-C-2 values were good for Hg(II) (0.06 and 0.73 mg L-1, respectively) and Pb(II) (0.08 and 0.87 mg L-1, respectively) and acceptable for Cu(II) (0.02 and 0.51 mg L-1, respectively). In conclusion, the obtained results showed that the developed approach is capable of resolve binary and ternary mixtures of Pb (II), Hg (II) and Cu (II), providing accurate information about lead (II) and mercury (II) concentration and signaling the occurrence of Cu (II).

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_talanta_2017_06_071.pdf 1467KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:2次