期刊论文详细信息
SENSORS AND ACTUATORS B-CHEMICAL 卷:252
Biosensing of hepatitis B antigen with poly(acrylic acid) hydrogel immobilized with antigens and antibodies
Article
Lim, Swee Lu1  Ooi, Chien-Wei1,2  Tan, Wen Siang3  Chan, Eng-Seng1,2  Ho, Kok Lian4  Tey, Beng Ti1,2 
[1] Monash Univ Malaysia, Sch Engn, Chem Engn Discipline, Jalan Lagoon Selatan, Bandar Sunway 47500, Selangor, Malaysia
[2] Monash Univ Malaysia, Adv Engn Platform, Jalan Lagoon Selatan, Bandar Sunway 47500, Selangor, Malaysia
[3] Univ Putra Malaysia, Fac Biotechnol & Biomol Sci, Dept Microbiol, Serdang 43400, Selangor, Malaysia
[4] Univ Putra Malaysia, Fac Med & Hlth Sci, Dept Pathol, Serdang 43400, Selangor, Malaysia
关键词: Hydrogel;    Acrylic acid;    Hepatitis B core antigen (HBcAg);    Bioresponsive;    Swelling;    Biosensor;   
DOI  :  10.1016/j.snb.2017.06.003
来源: Elsevier
PDF
【 摘 要 】

Hydrogel based on poly(acrylic acid) (PAAc) polymers was successfully fabricated as the biosensor for detecting hepatitis B core antigen (HBcAg). Specifically, the pendant HBcAg and the anti-hepatitis B core antigen (anti-HBc) antibody were first immobilized on the PAAc, which were then covalently cross-linked via radical polymerization to form the HBcAg-sensitive (HBPAAc) hydrogel. The non-covalent affinity binding between the immobilized HBcAg and anti-HBc would be disrupted by the presence of free HBcAg in the HBPAAc hydrogel. The competitive binding of free HBcAg on the immobilized anti-HBc triggered the swelling of HBPAAc hydrogel. The equilibrium swelling ratio and the oscillatory swelling-deswelling kinetics of the HBPAAc hydrogel in response to protein concentration were studied. The swelling ratio of HBPAAc hydrogel increased along with an increase in HBcAg concentration until equilibrium was achieved at 4 mg/mL HBcAg. The HBPAAc hydrogel did not exhibit swelling/deswelling behavior when interacted with the negative control, i.e., bovine serum albumin (BSA). Based on the result of oscillatory swelling-deswelling of HBPAAc hydrogel, the minimum duration for HBcAg detection by the HBPAAc hydrogel was similar to 20 min, whereas the regeneration of HBPAAc hydrogel took about 60 min. These results confirmed the reversibility and the reusability of this HBcAg-sensing HBPAAc hydrogel. Besides, the hydrogel demonstrated zero cross-reactivity to the hepatitis B surface antigen, a common serological marker for hepatitis B patients. The high sensitivity of HBPAAc hydrogel to the HBcAg was successfully demonstrated with quartz crystal microgravimetry. The magnitude of resonance frequency was inversely correlated with the swelling of HBPAAc hydrogel, which is governed by the concentration of analyte HBcAg. The application of HBPAAc hydrogel as a biosensor component in the detection and surveillance of hepatitis B holds great promises. (C) 2017 Elsevier B.V. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_snb_2017_06_003.pdf 1188KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:1次