Multi-wavelength spatial LED illumination based detector for in vitro detection of botulinum neurotoxin A activity
Article
Sun, Steven2,3  Francis, Jesse3  Sapsford, Kim E.2  Kostov, Yordan3  Rasooly, Avraham1,2 
[1] NCI, Rockville, MD 20892 USA
[2] US FDA, Div Biol, Off Sci & Engn Labs, Silver Spring, MD 20993 USA
[3] Univ Maryland Baltimore Cty, Baltimore, MD 21227 USA
关键词: LED;    Electroluminescent excitation;    CCD;    Fluorescence;    Forster Resonance Energy Transfer (FRET);    Botulinum neurotoxin A;    Biodetection;   
DOI  :  10.1016/j.snb.2010.02.009
来源: Elsevier
PDF
【 摘 要 】

A portable and rapid detection system for the activity analysis of botulinum neurotoxins (BoNT) is needed for food safety and bio-security applications. To improve BoNT activity detection, a previously designed portable charge-coupled device (CCD) based detector was modified and equipped with a higher intensity more versatile multi-wavelength spatial light-emitting diode (LED) illumination, a faster CCD detector and the capability to simultaneously detect 30 samples. A FITC/DABCYL Forster Resonance Energy Transfer (FRET)-labeled peptide substrate (SNAP-25), with BoNT-A target cleavage site sequence was used to measure BoNT-A light chain (LcA) activity through the FITC fluorescence increase that occurs upon peptide substrate cleavage. For fluorescence excitation, a multi-wavelength spatial LED illuminator was used and compared to our previous electroluminescent (EL) strips. The LED illuminator was equipped with blue, green, red and white LEDs, covering a spectrum of 450-680 nm (red 610-650 nm, green 492-550 nm, blue 450-495 nm, and white LED 440-680 nm). In terms of light intensity, the blue LED was found to be similar to 80-fold higher than the previously used blue EL strips. When measuring the activity of LcA the CCD detector limit of detection (LOD) was found to be 0.08 nM LcA for both the blue LED (2 s exposure) and the blue EL (which require >= 60s exposure) while the limits of quantitation (LOQ) is about 1 nM. The LOD for white LED was higher at 1.4 nM while the white EL was not used for the assay due to a high variable background. Unlike the weaker intensity EL illumination the high intensity LED illumination enabled shorter exposure times and allowed multi-wavelength illumination without the need to physically change the excitation strip, thus making spectrum excitation of multiple fluorophores possible increasing the versatility of the detector platform for a variety of optical detection assays. Published by Elsevier B.V.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_snb_2010_02_009.pdf 1253KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:0次