期刊论文详细信息
SENSORS AND ACTUATORS B-CHEMICAL 卷:327
Point-of-care DNA testing by automatically and sequentially performing extraction, amplification and identification in a closed-type cassette
Article
Dong, Tianhui1,2,3  Ma, Xueping2,3  Sheng, Nan1,2,3  Qi, Xiemin2,3  Chu, Yanan2,3  Song, Qinxin1  Zou, Bingjie2,3  Zhou, Guohua1,2,3,4 
[1] China Pharmaceut Univ, Sch Life Sci & Technol, Nanjing 210009, Peoples R China
[2] Nanjing Univ, Jinling Hosp, Med Sch, State Key Lab Analyt Chem Life Sci,Dept Clin Phar, Nanjing 210002, Peoples R China
[3] Nanjing Univ, Med Sch, Jiangsu Key Lab Mol Med, Nanjing 210002, Peoples R China
[4] Southern Med Univ, Sch Pharmaceut Sci, Guangzhou 510515, Peoples R China
关键词: Genetic test;    Cassette;    Point-of-care;    Colorimetric detection;    Magnetic separation;   
DOI  :  10.1016/j.snb.2020.128919
来源: Elsevier
PDF
【 摘 要 】

Nucleic acid detection is important for clinical diagnostics; however, it is challenging to perform genetic testing at the point-of-care due to the tedious steps involved in DNA extraction and the risk of cross-contamination from amplicons. To achieve a fully-automated and contamination-free nucleic acid detection, we propose a closedtype cassette system which enables the following steps to be operated automatically and sequentially: sample preparation based on magnetic beads, target amplification using multiplex polymerase chain reaction, and colorimetric detection of amplicons using a serial invasive reaction coupled with the aggregation of gold nanoparticle probes. The cassette was designed to be round and closed, and 10 targets in a sample could be simultaneously detected by the naked eye or using a spectrophotometer in the system. In addition, a cassette-driven device was fabricated to transfer reagents between wells, to control the temperature of each reaction, and to sense the colour in the detection wells. The cassette system was sensitive enough to detect 10 genotypes at 5 single nucleotide polymorphism sites related to the anticoagulant's usage, by using a 0.5 mu L blood sample. The accuracy of the system was evaluated by detecting 12 whole blood samples, and the results obtained were consistent with those obtained using pyrosequencing. The cassette is airtight and the whole system is fully automatic; the only manual operation is the addition of the sample to the cassette, performing point-of-care genetic testing in a sample-in/answer-out way.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_snb_2020_128919.pdf 2079KB PDF download
  文献评价指标  