SENSORS AND ACTUATORS B-CHEMICAL | 卷:228 |
An electrochemical immunosensor based on a 4,4′-thiobisbenzenethiol self-assembled monolayer for the detection of hemagglutinin from avian influenza virus H5N1 | |
Article | |
Jarocka, Urszula1  Sawicka, Roza2  Gora-Sochacka, Anna2  Sirko, Agnieszka2  Dehaen, Wim3  Radecki, Jerzy1  Radecka, Hanna1  | |
[1] Polish Acad Sci, Inst Anim Reprod & Food Res, Tuwima 10, PL-10748 Olsztyn, Poland | |
[2] Polish Acad Sci, Inst Biochem & Biophys, Pawinskiego 5A, PL-02106 Warsaw, Poland | |
[3] Univ Leuven, Dept Chem, Celestijnenlaan 200F, B-3001 Leuven, Belgium | |
关键词: 4,4'-Thiobisbenzenethiol; Avian influenza virus; scFv antibody fragments; Screen-printed gold electrodes; Miniaturization Electrochemical impedance spectroscopy; | |
DOI : 10.1016/j.snb.2016.01.001 | |
来源: Elsevier | |
【 摘 要 】
An electrochemical immunosensor for the detection of hemagglutinin from avian influenza virus H5N1 is presented in this paper. The following steps lead up to the construction of immunosensor: (i) modification of gold electrodes with 4,4'-thiobisbenzenethiol, (ii) modification of self-assembled monolayer of 4,4'-thiobisbenzenethiol with gold colloidal nanoparticles, (iii) immobilization of single chain variable fragments of antibodies (scFv) against hemagglutinin H5 via S Au covalent bonds, (iv) blocking of the remaining free space with bovine serum albumin. The interactions between the scFv and hemagglutinin variants have been explored with electrochemical impedance spectroscopy in the presence of [Fe(CN)(6)](3-/4-) as an electroactive marker. The immunosensor was able to detect two different His-tagged variants of recombinant hemagglutinin from H5N1 viruses: the short fragment (17-340 residues) of A/swan/Poland/305-135V08/2006 and the long (17-530 residues) of A/Bar-headed Goose/Qinghai/12/2005. The strongest response has been observed for the long variant with a detection limit of 0.6 pg/mL and a dynamic range from 4.0 to 20.0 pg/mL. The recombinant hemagglutinin (17-527 residues) from A/chicken/Netherlands/1/03 (H7N7), used as the negative control generated a weak response. This confirms the selectivity of the immunsensor proposed. A miniaturized version of the immunosensor, based on screen-printed gold electrodes, was tested with the same set of recombinant hemagglutinins and it achieved a linear range from 1 to 8 pg/mL with a detection limit of 0.9 pg/mL for the long fragment of hemagglutinin. (C) 2016 Elsevier B.V. All rights reserved.
【 授权许可】
Free
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
10_1016_j_snb_2016_01_001.pdf | 979KB | download |