期刊论文详细信息
SENSORS AND ACTUATORS B-CHEMICAL 卷:255
Bloch surface wave label-free and fluorescence platform for the detection of VEGF biomarker in biological matrices
Article
Rizzo, Riccardo1  Alvaro, Maria2,3  Danz, Norbert4  Napione, Lucia2,3  Descrovi, Emiliano1  Schmieder, Stefan5  Sinibaldi, Alberto6  Chandrawati, Rona7,11  Rana, Subinoy7  Munzert, Peter4  Schubert, Thomas8  Maillart, Emmanuel9  Anopchenko, Aleksei6,12  Rivolo, Paola1  Mascioletti, Alessandro10  Sonntag, Frank5  Stevens, Molly M.7  Bussolino, Federico2,3  Michelotti, Francesco6 
[1] Politecn Torino, Dept Appl Sci & Technol, Cso Duca Abruzzi 24, I-10129 Turin, Italy
[2] IRCCS, Candiolo Canc Inst, Lab Vasc Oncol, Candiolo, Italy
[3] Univ Torino, Dept Oncol, Candiolo, Italy
[4] Fraunhofer Inst Appl Opt & Precis Engn I0F, Albert Einstein Str 7, D-07745 Jena, Germany
[5] Fraunhofer Inst Mat & Beam Technol IWS Dresden, D-01277 Dresden, Germany
[6] Sapienza Univ Rome, Dept Basic & Appl Sci Engn, Via A Scarpa 16, I-00161 Rome, Italy
[7] Imperial Coll London, Dept Mat, London SW7 2AZ, England
[8] KDS Raderberger GmbH, D-01900 Grosshansdorf, Germany
[9] HORIBA Sci, Av Vauve CS 45002, F-91120 Palaiseau, France
[10] LABOR Srl, Via G Peroni, I-00131 Rome, Italy
[11] Univ Sydney, Sch Chem & Biomol Engn, Sydney, NSW 2006, Australia
[12] Baylor Univ, Dept Phys, One Bear Pl 97316, Waco, TX 76798 USA
关键词: Biosensor platform;    Bloch surface waves;    Label-free optical sensor;    Enhanced fluorescence;    Tumor biomarker;    Complex matrices;   
DOI  :  10.1016/j.snb.2017.09.018
来源: Elsevier
PDF
【 摘 要 】

We report on the detection of an angiogenic molecule Vascular Endothelial Growth Factor (VEGF) in different biological matrices by means of a new integrated biosensing platform exploiting the properties of Bloch surface waves. The new platform takes advantage of a tandem configuration, in which both label-free and enhanced fluorescence detection are implemented. Specifically designed one dimensional photonic crystals were deposited directly on disposable and low cost plastic biochips. A direct sandwich immunoassay was used to detect VEGF in buffer, cell culture supernatant and human plasma at low concentration (ng/mL). The platform enabled the detection of VEGF in all three matrices with high resolution, fast turnaround time (30 min) and in close agreement with the results of enzyme linked immunosorbent assays. (C) 2017 Elsevier B.V. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_snb_2017_09_018.pdf 973KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:0次