3-D printed adjustable microelectrode arrays for electrochemical sensing and biosensing
Article
Yang, Haipeng1,2,3  Rahman, Md Taibur1  Du, Dan1  Panat, Rahul1  Lin, Yuehe1 
[1] Washington State Univ, Sch Mech & Mat Engn, Pullman, WA 99164 USA
[2] Shenzhen Univ, Coll Mat Sci & Engn, Nanshan Dist Key Lab Biopolymers & Safety Evaluat, Shenzhen 518060, Peoples R China
[3] Shenzhen Univ, Shenzhen Key Lab Special Funct Mat, Shenzhen 518060, Peoples R China
关键词: Microelectrode arrays;    Micro additive manufacturing;    Hydrogen peroxide;    Electrochemical sensor;    Biosensor;   
DOI  :  10.1016/j.snb.2016.02.113
来源: Elsevier
PDF
【 摘 要 】

Printed electronics has emerged as an important fabrication technique that overcomes several shortcomings of conventional lithography and provides custom rapid prototyping for various sensor applications. In this work, silver microelectrode arrays (MEA) with three different electrode spacing were fabricated using 3-D printing by the aerosol jet technology. The microelectrodes were printed at a length scale of about 15 mu m, with the space between the electrodes accurately controlled to about 2 times (30 mu m, MEA30), 6.6 times (100 mu m, MEA100) and 12 times (180 mu m, MEA180) the trace width, respectively. Hydrogen peroxide and glucose were chosen as model analytes to demonstrate the performance of the MEA for sensor applications. The electrodes are shown to reduce hydrogen peroxide with a reduction current proportional to the concentration of hydrogen peroxide for certain concentration ranges. Further, the sensitivity of the current for the three electrode configurations was shown to decrease with an increase in the microelectrode spacing (sensitivity of MEA30:MEA100:MEA180 was in the ratio of 3.7:2.8:1), demonstrating optimal MEA geometry for such applications. The noise of the different electrode configurations is also characterized and shows a dramatic reduction from MEA30 to MEA100 and MEA180 electrodes. Further, it is shown that the response current is proportional to MEA100 and MEA180 electrode areas, but not for the area of MEA30 electrode (the current density of MEA30:MEA100:MEA180 is 0.25:1:1), indicating that the MEA30 electrodes suffer from diffusion overlap from neighboring electrodes. The work thus establishes the lower limit of microelectrode spacing for our geometry. The lowest detection limit of the MEAs was calculated (with S/N = 3) to be 0.45 mu M. Glucose oxidase was immobilized on MEA100 microelectrodes to demonstrate a glucose biosensor application. The sensitivity of glucose biosensor was 1.73 mu A mM(-1) and the calculated value of detection limit (S/N = 3) was 1.7 mu M. The electrochemical response characteristics of the MEAs were in agreement with the predictions of existing models. The current work opens up the possibility of additive manufacturing as a fabrication technique for low cost custom-shaped MEA structures that can be used as electrochemical platforms for a wide range of sensor applications. (C) 2016 Elsevier B.V. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_snb_2016_02_113.pdf 1370KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:0次