Mechanistic modeling of cyclic voltammetry: A helpful tool for understanding biosensor principles and supporting design optimization
Article
Semenova, Daria1  Zubov, Alexandr1  Silina, Yuliya E.2  Micheli, Laura3  Koch, Marcus2  Fernandes, Ana C.1  Gernaey, Krist V.1 
[1] Tech Univ Denmark, Dept Chem & Biochem Engn, Proc & Syst Engn Ctr PROSYS, Bldg 229, DK-2800 Lyngby, Denmark
[2] INM Leibniz Inst New Mat, Campus D2 2, D-66123 Saarbrucken, Germany
[3] Univ Roma Tor Vergata, Dept Chem Sci & Technol, Via Ric Sci 1, I-00133 Rome, Italy
关键词: Mechanistic modeling;    Cyclic voltammograms;    Amperometric biosensors;    Glucose biosensors;    SEM/EDX;    LC-ESI-MS/MS;   
DOI  :  10.1016/j.snb.2017.12.088
来源: Elsevier
PDF
【 摘 要 】

Design, optimization and integration of biosensors hold a great potential for the development of cost-effective screening and point-of-care technologies. However, significant progress in this field can still be obtained on condition that sufficiently accurate mathematical models will be developed. Herein, we present a novel approach for the improvement of mechanistic models which do not only combine the fundamental principles but readily incorporate the results of electrochemical and morphological studies. The first generation glucose biosensors were chosen as a case study for model development and to perform cyclic voltammetry (CV) measurements. As initial step in the model development we proposed the interpretation of experimental voltammograms obtained in the absence of substrate (glucose). The model equations describe dynamic diffusion and reaction of the involved species (oxygen, oxidized/reduced forms of the mediator - Prussian Blue/Prussian White). Furthermore, the developed model was applied under various operating conditions as a crucial tool for biosensor design optimization. The obtained qualitative and quantitative dependencies towards amperometric biosensors design optimization were independently supported by results of cyclic voltammetry and multi-analytical studies, such as scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX) and liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS). Remarkably, a linear response of the optimized biosensors tested at the applied voltage (-0.14 V) in the presence of the glucose was obtained from 10(-3) to 10(-5) M (relative standard deviation (RSD) <7% per electrode). We believe that the presented model can be used to determine the exact mechanism driving the electrochemical reactions and to identify critical system parameters affecting the biosensor response that would significantly contribute to the knowledge on biosensing, device's design and bioengineering strategies in the future. (c) 2017 Elsevier B.V. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_snb_2017_12_088.pdf 2827KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:0次