期刊论文详细信息
SENSORS AND ACTUATORS B-CHEMICAL 卷:262
Ratiometric fluorescence sensor based on dithiothreitol modified carbon dots-gold nanoclusters for the sensitive detection of mercury ions in water samples
Article
Liu, Wen1,2  Wang, Xiaoyan1,2,3  Wang, Yunqing2  Li, Jinhua2  Shen, Dazhong1  Kang, Qi1  Chen, Lingxin2 
[1] Shandong Normal Univ, Shandong Univ, Shandong Prov Key Lab Clean Prod Fine Chem,Minist, Collaborat Innovat Ctr Functionalized Probes, Jinan 250014, Shandong, Peoples R China
[2] Chinese Acad Sci, Yantai Inst Coastal Zone Res, Res Ctr Coastal Environm Engn Technol Shandong Pr, Key Lab Coastal Environm Proc & Ecol Remediat, Yantai 264003, Peoples R China
[3] Binzhou Med Univ, Sch Pharm, Yantai 264003, Peoples R China
关键词: Mercury ions;    Ratiometric fluorescence;    Carbon dots-gold nanoclusters;    Dithiothreitol;    Water samples;   
DOI  :  10.1016/j.snb.2018.01.222
来源: Elsevier
PDF
【 摘 要 】

Ratiometric fluorescence sensors can provide more accurate analysis of target objects because of their self-calibration function. Traditional methods often use steps of chemical coupling with two different fluorescent materials as the dual emission source, which make the construction process complicated and hard to control. Here, we report a convenient and effective way to construct a ratiometric fluorescence sensor based on dual-emission carbon dots-gold nanoclusters (C-AuNCs) functionalized with dithiothreitol (DTT) for the sensitive detection of mercury ions (Hg2+) in water samples. As a type of novel nanoparticle, C-AuNCs are synthesized via microwaving a mixture of gold seeds solution and carbon precursor. In the presence of Hg2+, the free thiol group of DTT would attract them around the surface of C-AuNCs, and owing to the strong 5d(10)-5d(10) metallophilic interactions between Hg2+ and Au+, the fluorescence emission at 598 nm is quenched while the emission at 466 nm remains at a constant intensity. Thus, an obvious color change from orange-red to blue under ultraviolet irradiation can be observed by the naked eye. Moreover, the as-prepared fluorescence sensor has high sensitivity with a detection limit of 8.7 nM, and successfully applies to detect Hg2+ in real water samples with satisfactory recoveries at three spiking levels ranging from 95.9 - 103.5%. The good results imply that the developed DTT/C-AuNCs sensor is conducive to trace Hg2+ determination and possesses the great application potential for water-quality monitoring. (C) 2018 Elsevier B.V. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_snb_2018_01_222.pdf 1135KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:0次