期刊论文详细信息
SENSORS AND ACTUATORS B-CHEMICAL 卷:248
Rapid and repetitive immunoassay with a surface acoustic wave device for monitoring of dust mite allergens
Article
Toma, Koji1  Horibe, Mai2  Kishikawa, Chisato3  Yoshimura, Naoyuki4  Arakawa, Takahiro1  Yatsuda, Hiromi4,5  Shimomura, Hiroji2  Mitsubayashi, Kohji1,3 
[1] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Dept Biomed Devices & Instrumentat, Tokyo 1010062, Japan
[2] Bunkyo Gakuin Univ, Fac Hlth Sci Technol, Tokyo 1138668, Japan
[3] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Tokyo 1138510, Japan
[4] Japan Radio Co Ltd, Saitama 3568510, Japan
[5] OJ Bio Ltd, Newcastle Upon Tyne NE1 4EP, Tyne & Wear, England
关键词: Rapid;    Repetitive;    Surface acoustic wave;    Immunosensor;    House dust mite allergen;   
DOI  :  10.1016/j.snb.2017.01.183
来源: Elsevier
PDF
【 摘 要 】

In this work, we investigated a new approach to shorten a measurement time of house dust mite (HDM) allergens with a surface acoustic wave (SAW) immunosensor for improvement of continuity in monitoring of airborne HDM. It was achieved by employing differential method with which a slope of phase change was used as a sensor output instead of a phase shift that was used conventionally. Compared to the conventional method, measurement time of Group 1 HDM allergens of Dermatophagoides farinae (Der f 1) was shortened by 10 min from 30 min, while a sensitivity of SAW immunosensor was comparable (limit of detection of 20.1 ng/mL). 300 ng/mL Der f 1 was repeatedly measured ten times by the differential method, and it resulted in highly reproduced sensor output as represented by a coefficient of variation of 5.7%. In addition, due to smaller amount of bound detection antibodies on the sensor surface, decline of the baseline during the semi-continuous measurement that happened in the conventional method was not observed. Selectivity of the differential method was also investigated with four different common environmental allergens including Der f 1. No significant output was observed from the samples without Der f 1, and a high selectivity of the differential method with SAW immunosensor was validated. These results suggest that use of the differential method with SAW immunosensor would lead to advanced semi-continuous measurement with high continuity of airborne HDM allergens when it is incorporated with a monitoring system. (C) 2017 Elsevier B.V. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_snb_2017_01_183.pdf 1435KB PDF download
  文献评价指标  
  下载次数:29次 浏览次数:0次