期刊论文详细信息
SENSORS AND ACTUATORS B-CHEMICAL 卷:193
Depletion of cells and abundant proteins from biological samples by enhanced dielectrophoresis
Article; Proceedings Paper
Javanmard, M.1  Emaminejad, S.1,2  Gupta, C.2  Provine, J.2  Davis, R. W.1  Howe, R. T.2 
[1] Stanford Univ, Stanford Genome Technol Ctr, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
关键词: Microfluidics;    Particle actuation;    Dielectrophoresis;    Sample preparation;    Cell depletion;   
DOI  :  10.1016/j.snb.2013.11.100
来源: Elsevier
PDF
【 摘 要 】

Platforms that are sensitive and specific enough to assay low-abundance protein biomarkers, in a high throughput multiplex format, within a complex biological fluid specimen, are necessary to enable protein biomarker based diagnostics for diseases such as cancer. The signal from an assay for a low-abundance protein biomarker in a biological fluid sample like blood is typically buried in a background that arises from the presence of blood cells and from high-abundance proteins that make up 90% of the assayed protein mass. We present an automated on-chip platform for the depletion of cells and highly abundant serum proteins in blood. Our platform consists of two components, the first of which is a microfluidic mixer that mixes beads containing antibodies against the highly abundant proteins in the whole blood. This complex mixture (consisting of beads, cells, and serum proteins) is then injected into the second component of our microfluidic platform, which comprises a filter trench to capture all the cells and the beads. The size-based trapping of the cells and beads into the filter trench is significantly enhanced by leveraging additional negative dielectrophoretic forces to push the micron sized particles (cells and beads which have captured the highly abundant proteins) down into the trench, allowing the serum proteins of lower abundance to flow through. In general, dielectrophoresis using bare electrodes is incapable of producing forces beyond the low piconewton range that tend to be insufficient for separation applications. However, by using electrodes passivated with atomic layer deposition, we demonstrate the application of enhanced negative DEP electrodes together with size-based filtration induced by the filter trench, to deplete 100% of the micron sized particles in the mixture. (C) 2013 Elsevier B.V. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_snb_2013_11_100.pdf 1664KB PDF download
  文献评价指标  
  下载次数:18次 浏览次数:1次