期刊论文详细信息
RENEWABLE & SUSTAINABLE ENERGY REVIEWS 卷:119
On-design pre-optimization and off-design analysis of hybrid Brayton thermosolar tower power plants for different fluids and plant configurations
Article
Merchan, R. P.1,2  Santos, M. J.1,2  Heras, I.1,2  Gonzalez-Ayala, J.1,2  Medina, A.1,2  Calvo Hernandez, A.1,2 
[1] Univ Salamanca, Dept Appl Phys, E-37008 Salamanca, Spain
[2] Univ Salamanca, Inst Fundamental Phys & Math IUFFYM, E-37008 Salamanca, Spain
关键词: Thermosolar hybrid plants;    Multi-stage bray ton;    On-design pre-optimization;    Off-design analysis;    Greenhouse emissions;   
DOI  :  10.1016/j.rser.2019.109590
来源: Elsevier
PDF
【 摘 要 】

A working fluid performs a Brayton cycle that is fed by a heat input from a solar power tower and from a combustion chamber, which burns natural gas. This hybrid system is described by a complete model that includes all the main losses and irreversibility sources (optical and thermodynamic). Numerical implementation and validation is performed based on a Spanish commercial plant. On-design computations are carried out varying the pressure ratio for four working fluids (dry air, nitrogen, carbon dioxide, and helium), for different number of stages and for recuperative and non-recuperative configurations. When adjusting the pressure ratio, an improvement of about 7 % in overall thermal efficiency is predicted for a dry air single-stage recuperative configuration with respect to a standard commercial gas turbine. A study about the main energy losses in each plant subsystem for some particular plant layouts is accomplished. A two-compression and expansion stages recuperative Brayton cycle working with air is expected to give overall thermal efficiencies about 0.29 at design conditions, which is about a 47% increase with respect to the simplest single-stage configuration. It is stressing that fuel consumption from the reheaters maybe higher than that of the main combustion chamber for multi-stage layouts. Off-design hourly curves of output records for the four seasons throughout a day are analyzed. Greenhouse emissions are also analyzed. Specific carbon dioxide emissions are smaller for helium than for dry air, when they both work in a single-stage non-recuperative configuration.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_rser_2019_109590.pdf 3973KB PDF download