Long-term power degradation analysis of crystalline silicon PV modules using indoor and outdoor measurement techniques
Article
Carigiet, Fabian1,2  Brabec, Christoph J.2,3  Baumgartner, Franz P.1 
[1] ZHAW Zurich Univ Appl Sci, Sch Engn, Inst Energy Syst & Fluid Engn, Technikumstr 9, CH-8401 Winterthur, Switzerland
[2] FAU Friedrich Alexander Univ Erlangen Nurnberg, Inst Mat Elect & Energy Technol, Martensstr 7, D-91058 Erlangen, Germany
[3] Forschungszentrum Julich, HI ErN Helmholtz Inst Erlangen Nurnberg, Immerwahrstr 2, D-91058 Erlangen, Germany
关键词: c-Si solar cell;    Outdoor test field;    Solar simulator measurement;    Outdoor performance monitoring;    Performance ratio;    Degradation rate;   
DOI  :  10.1016/j.rser.2021.111005
来源: Elsevier
PDF
【 摘 要 】

Annual degradation rates of PV modules are important in the yield prediction. For a high-quality PV module, these rates are lower than the measurement uncertainty of a nominal power measurement performed in todays most advanced certified photovoltaic reference laboratory. Therefore, the analysis requires a well thought out methodology that can compare the data relative to each other or relative to an unused module stored in the dark on an annual base. Over the past 10 years, several multi c-Si and HIT modules have been accurately monitored in a string and single module setup by an outdoor performance measurement system. Additionally, all modules have been dismantled and measured using an indoor flasher measurement system once every year. With this unique measurement setup, the annual degradation rates of multi c-Si modules and HIT modules are quantified based on three different analysis methodologies. The multi c-Si modules showed an average annual degradation rate of 0.18% +/- 0.06% and 0.29% +/- 0.06% measured by the outdoor and indoor system, respectively. The indoor analysis of the HIT modules yielded an average annual degradation of 0.26% +/- 0.05%. That corresponds to half of the degradation observed by the outdoor analysis method. Further evaluations of the performance ratio PR confirmed the results gained by the indoor methodology. The comparison of the standard PR with a temperaturecorrected PR'STC for both technologies showed that the benefit of the lower temperature coefficient of the HIT technology is eliminated by its worse low light behaviour.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_rser_2021_111005.pdf 3326KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:2次