期刊论文详细信息
RENEWABLE & SUSTAINABLE ENERGY REVIEWS 卷:150
Experimental Analysis of hill-climbing MPPT algorithms under low irradiance levels
Article
Jately, Vibhu1  Azzopardi, Brian1  Joshi, Jyoti2  Venkateswaran, Balaji V.3  Sharma, Abhinav4  Arora, Sudha2 
[1] Malta Coll Arts Sci & Technol MCAST, MCAST Energy Res Grp MCAST Energy, Triq Kordin 9032, Paola Pla, Malta
[2] GB Pant Univ Agr & Technol, Dept Elect Engn, Pantnagar 263145, Uttar Pradesh, India
[3] Woxsen Univ, Sch Technol, Hyderabad 502345, Telangana, India
[4] Univ Petr & Energy Studies, Dept Elect & Elect Engn, Dehra Dun 248007, Uttarakhand, India
关键词: Hill-climbing;    MPPT;    Perturb and Observe;    Perturbation step-size;    ADC;    Incremental conductance;   
DOI  :  10.1016/j.rser.2021.111467
来源: Elsevier
PDF
【 摘 要 】

Adaptive hill-climbing MPPT algorithms have superior performance as opposed to their conventional counterparts under medium-high irradiance. However, the performance of these hill-climbing algorithms remains mostly unknown under low irradiance condition. The low irradiance conditions are prominent in tropical countries during rainy seasons and niche PV applications. Additionally, several thin-film photovoltaic (PV) technologies have better efficiency under low irradiance conditions. Hence, the optimum operation of MPPT algorithms under low irradiance conditions is vital. In the real-time implementation, MPPT algorithms can fail to detect the incremental changes in voltage and current under low irradiance conditions. Hence, analog to digital converter (ADC) resolution becomes a critical constraint that governs the performance of hill-climbing (HC) MPPT algorithms. This work entails a detailed calculation to determine the perturbation step-sizes of the MPPT algorithms under a wide range of irradiance. Two distinct perturbation step-sizes are determined corresponding to the minimum and optimum change in voltage and current due to perturbation, that is sensed by the ADC. The authors also defined a general expression to determine the optimum digitized step-size for duty-based perturb and observe algorithm under low irradiance condition. This expression is formulated by considering the resolution of the ADC and the desirability of keeping the power oscillations at an acceptable level. Finally, the performance of eight hill-climbing algorithms for two distinct step-sizes is analyzed on a small-scale experimental prototype under both uniform and sudden changes in low values of irradiance. The statistical analysis validates that the adaptive HC drift-free MPPT algorithm outperforms other HC algorithms when implemented with the optimum perturbation step-size under low irradiance conditions.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_rser_2021_111467.pdf 9201KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:2次