期刊论文详细信息
RENEWABLE ENERGY 卷:36
Three-dimensional analysis and investigation of the thermal and hydrodynamic behaviors of cylindrical storage tanks
Article
Savicki, Darci L.2  Vielmo, Horacio A.2  Krenzinger, Arno1 
[1] Univ Fed Rio Grande do Sul, Dept Mat Engn, BR-90170050 Porto Alegre, RS, Brazil
[2] Univ Fed Rio Grande do Sul, Dept Mech Engn, BR-90170050 Porto Alegre, RS, Brazil
关键词: Storage tanks;    Three-dimensional numerical analysis;    Finite volume method;   
DOI  :  10.1016/j.renene.2010.10.011
来源: Elsevier
PDF
【 摘 要 】

A numerical analysis of the three-dimensional temperature and velocity fields in horizontal cylindrical storage tanks was performed. The phenomena of laminar natural convection and vertical stratification of temperature were considered. The developed three-dimensional transient computing code solves the equations of energy and momentum through the finite volume method. The simulation of fluid cooling process inside the tank showed the formation of stratified temperature profiles that matched those obtained experimentally. Based on several simulations, a correlation was proposed for determining the degree of thermal stratification inside the tank regarding thermal and geometrical parameters. From this correlation, an expression was proposed to predict the fluid temperature profiles along the time. This information is very important in many applications, such as in thermosiphon solar water heating systems, where the global efficiency of the system increases with the thermal stratification degree of the working fluid. Another case studied considered that the tank was connected to solar collectors, aiming at investigating the influence of the inlet jet position with and without a baffle plate on the preservation of the thermal stratification. Results showed that the baffle plate modified the velocity and temperature fields close to the inlet jet, allowing a better thermal stratification. Also the suitable choice of the inlet jet position allowed the formation of a more effective thermal stratification. Some other aspects of the internal dynamics of this kind of storage tank are presented and discussed. For the cases studied, the inlet jet next to the top led to a greater thermal stratification. However, it was verified that when the inlet jet temperature remains constant for a long period of time, and thus its temperature approaches the temperature of the water inside the tank, for the same height, the temperature profiles obtained become similar to the case of the inlet located at usual height of 2/3 of the diameter. (C) 2010 Elsevier Ltd. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_renene_2010_10_011.pdf 1443KB PDF download
  文献评价指标  
  下载次数:2次 浏览次数:0次