期刊论文详细信息
JOURNAL OF THE NEUROLOGICAL SCIENCES 卷:415
An automated alert system based on the p-Tau/Tau ratio to quickly inform health professionals upon a suspected case of sporadic Creutzfeldt-Jakob disease
Article
Foucault-Fruchard, Laura1,8  Delaye, Jean Baptiste2  Morange, Virginie3  Beaufils, Emilie4,8  Duwicquet, Coline5  Quadrio, Isabelle6,7  Balageas, Anna Chloe4,8  Dufour-Rainfray, Diane2,8,9 
[1] CHU Tours, Serv Pharm, F-37044 Tours, France
[2] CHU Tours, Serv Med Nucl Vitro, F-37044 Tours, France
[3] CHU Tours, Equipe Operat Hyg, F-37044 Tours, France
[4] CHU Tours, Ctr Memoire Ressources & Rech CMRR, F-37044 Tours, France
[5] CHU Tours, Serv Neurol, F-37044 Tours, France
[6] Hosp Civils Lyon, Serv Biochim & Biol Mol Grand Est, Unite Pathol Neurodegenerat, Lyon, France
[7] Univ Lyon, Equipe BIORAN Ctr Rech Neurosci Lyon, CNRS UMR INSERM U1028 5292, Lyon, France
[8] Univ Tours, INSERM, iBrain, UMR 1253, Tours, France
[9] Soc Francaise Med Nucl, Grp Biol Specialisee, Paris, France
关键词: Creutzfeldt-Jakob disease;    Iatrogenic transmission;    Alert system;    Hygiene measures;   
DOI  :  10.1016/j.jns.2020.116971
来源: Elsevier
PDF
【 摘 要 】

Introduction: Knowing the risk of potential sporadic Creutzfeldt-Jakob disease (sCJD) instrument-contamination is essential in hospitals. We examined the relevance of the p-Tau/Tau ratio to exclude a probable case of sCJD in clinical practice, and we established an alert system to quickly inform health professionals in case of positivity. Methods: This retrospective study was conducted on 143 cerebrospinal fluid samples from patients suspected for sCJD. The distinction between probable cases of sCJD and other patients was based on clinical, paraclinical and biological (14-3-3, Tau, p-Tau, A beta 1-42) data. From this experience, the health professionals developed an alert system to be implemented upon a suspected case of sCJD. Results: A significant decrease in p-Tau/Tau ratio between sCJD and the other diseases was observed (p < 0.001). The combined Tau test presented a sensitivity higher than 14-3-3 (100% versus 92.3%, p = 0.006) and an equivalent specificity (90% versus 96.1%). The time required for obtaining results was higher for 14-3-3 due to the centralization of investigations in some laboratories (3 weeks versus 2 h). In the presence of these elements, the triggering of the alert system was based on the p-Tau/Tau ratio. This system involves sending an automatic mail to the hospital department involved in the patient's care and the hospital hygiene team, which oversees the application of the procedures. Conclusion: The p-Tau/Tau concentrations present the desired criteria for use in current medical practice to fight against iatrogenic transmission. The alert system confirms a probable case of sCJD instantly to health professionals. Hygiene and sterilization measures can be applied immediately.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_jns_2020_116971.pdf 780KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:0次