期刊论文详细信息
JOURNAL OF HEART AND LUNG TRANSPLANTATION 卷:33
Predictors of hospital length of stay after implantation of a left ventricular assist device: An analysis of the INTERMACS registry
Article
Cotts, William G.1  McGee, Edwin C., Jr.2  Myers, Susan L.3  Naftel, David C.3  Young, James B.4  Kirklin, James K.5  Grady, Kathleen L.2 
[1] Advocate Christ Med Ctr, Inst Heart & Vasc, Oak Lawn, IL 60453 USA
[2] Northwestern Univ, Dept Surg, Div Cardiac Surg, Chicago, IL USA
[3] Univ Alabama Birmingham, Cardiovasc Surg Res, Birmingham, AL USA
[4] Cleveland Clin, Dept Med,Endocrinol & Metab Inst, Cleveland, OH USA
[5] Univ Alabama Birmingham, Dept Cardiothorac Surg, Birmingham, AL USA
关键词: heart failure;    ventricular assist device;    length of stay;    continuous flow;    mechanical circulatory support;   
DOI  :  10.1016/j.healun.2014.02.022
来源: Elsevier
PDF
【 摘 要 】

BACKGROUND: Few studies have reported on hospital length of stay (LOS) after left ventricular assist device (LVAD) implantation. The purpose of this study was to determine pre- and peri-operative predictors of hospital LOS after LVAD implantation. METHODS: We analyzed adult primary continuous-flow LVAD patients implanted between June 23, 2006 and December 31, 2010 at 105 institutions from the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS). Retrospective analyses included measures of central tendency, frequencies, correlations and stepwise multivariable regression modeling (p <= 0.05). Independent variables included demographic characteristics, pre-implant clinical and behavioral variables and concomitant surgery. RESULTS: Characteristics of the patients (n = 2,200) included: mean age 54.6 +/- 12.6 years; 79% male; 69% white; 57% INTERMACS Profile 1 or 2; 37% diabetic; 21% with history of coronary artery bypass graft (CABG); 7% with history of valve surgery; and 37% with concomitant surgery. Median hospital LOS (implant to discharge) was 20 days. Significant predictors of an increased hospital LOS included demographic characteristics (older age and non-white), pre-implant clinical variables (history of CABG or valve surgery, diabetes, ascites, INTERMACS Profiles 1 and 2, low albumin, high blood urea nitrogen, high right atrial pressure) and concomitant surgery, explaining 12% variance (F = 22.65, p < 0.001). CONCLUSIONS: Demographic characteristics, pre-implant variables and concomitant surgery partially explained hospital LOS after continuous-flow LVAD implant. These variables have implications regarding selection of patients for mechanical circulatory support. (C) 2014 International Society for Heart and Lung Transplantation. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_healun_2014_02_022.pdf 1343KB PDF download
  文献评价指标  
  下载次数:16次 浏览次数:0次